www.insigniashowers.com
Last Modified: 06/05/2022
05
Model/Power
Phase
Heating Elements
Voltage/Current
Power Wire
Breaker
Room Volume
Dimensions
kW
1/3
Number x kW
V/A
Number x
Amps
m³
Length x Width x Height
AIO 7.5kW
1
3 x 2.5
215
-
240/33.75
3 x 6.0
60
6.5
—
9
475 x 185 x 450
AIO 7.5kW
3
3 x 2.5
380
-
415/11.25
5 x 2.5
16
6.5
—
9
475 x 185 x 450
AIO 10.5kW
3
3 x 1.5 + 3 x 2
380
-
415/15.9
5 x 2.5
25
9
—
12
475 x 185 x 450
AIO 12kW
3
6 x 2
380
-
415/18.2
5 x 2.5
25
11
—
14
475 x 185 x 450
AIO 15kW
3
6 x 2.5
380
-
415/22.7
5 x 2.5
32
13
—
18
510 x 185 x 460
AIO 18kW
3
9 x 2
380
-
415/27.3
5 x 4
40
16
—
22
510 x 185 x 460
Models, Parameters and Dimensions
1.
The rated power is measured under single phase 230V, therefore the actual operating power under single phase 215
-
240V, 50/60Hz,
or three phases 380
-
415V, 50/60Hz may be different from the rated value.
2.
The 7.5kW generator, can be made as 215
-
240V single phase or 380
-
415V three phases. Please note the earth wire should not be less
than 1.5mm², the live wire and null wire should not less than 2.5mm².
3.
The 10.5kW, 12kW, 15kW and 18kW generators, can be only be installed by 380
-
415V three phases. Please note the earth wire should
not be less than 2.5mm², the live wire and null wire should not be less than 4.0mm².
How to choose the right kW steam generator?
On our website we have an online calculator to give you the information on exactly what steam generator we recommend for your steam
room.