Troubleshooting
Repair can only be performed by qualified professionals, for more services or technical help please contact your retailer.
Insignia Signature steam generator have a self
-
diagnose function, and some common faults will be displayed on the screen if they occur.
Code
Meaning
Diagnose and Solution
-
L
Temperature measured by temperature sensor is
below 6 °C
Check whether the room temperature is below 6 °C, the code should disappear
after the room temperature reaches 6 °C. Otherwise check the connection of
-
H
Temperature measured by temperature sensor is
higher than 60 °C
Check whether the room temperature is above 60 °C, the code should
disappear after the room temperature drops below 60 °C. Otherwise check the
connection of the sensor.
-
E
Water supply or water fill faults, the heating
elements will not heat up or stop heating up.
Check whether the water inlet solenoid valve works. Check the valve on the
water pipeline or water supply source. Check the treatment cartridge (if
installed). Check whether the water level sensor connection cable is intact and
connected. If any problem is on these items, clean or remove/replace, then
restart the machine to see if you have resolved the problem.
EE
Communication fault between the controller and
circuit board on the central box.
Please check the connection cable wire is connected and not damaged.
d
or
dd
Time runs out or pressed the
“
ON/OFF
”
button,
machine will stop working and go in the auto
drain progress.
No issue, this is normal behaviour for the generator