www.insigniashowers.com
Last Modified: 06/05/2022
38
Auto Functions
Auto filling:
The inlet valve will open automatically once the system has started and fill water until the water level reaches it
’
s maximum level. If the water level is still
lower than the minimum water level 10 after minutes, it indicates a fault of the water supply system, so all heating elements will stop working. If the
screen display shows
“
”,
this means it
’
s filling with water.
Auto heating up by sections:
The Steam Generator will compare the measured room temperature with the setting temperature and then decides the number of working heating
elements for the best efficiency.
Auto water supplementing:
If the water level is lower than the desired level when operating, auto
-
water supplementing function will be on and open the inlet valve, the screen will
display
“
”.
Once the water level reaches the desired level, the auto
-
water supplementing function turns off. If the water level is lower than
the desired level 3 minutes after the water supplementing order is activated, it indicates faults of the water supply system, so all heating elements stop
working.
Auto drainage:
If the descaling time is set as
“0”,
when the steam generator is turned off, the system will drain automatically and display
‘
”
on the screen. The
drainage valve will be turned on to drain. If the Descaling time is NOT set as
“0”,
please ref to
“
Descaling
”.