7
INSTALLATION
INSTALLATION
2�1 Unit placement
The siting of the device must be established by the system
designer or other qualified professional and must take into
account both technical requirements and any local laws in
force.
The Filomuro fancoil has to be installed only in high po-
sition on the wall, with a maximum height of 2,2 m (ex-
cept for use in cooling only).
Avoid installing the unit near:
• areas exposed to direct sunlight
• near heat sources
• in damp areas and areas in which the unit can come into
contact with water
• in environments with oil mists
• in environments subject to high frequencies
Make sure that:
• the wall on which you intend to install the unit has an ap-
propriate structure and capacity
• the wall surface is not crossed by pipelines or power lines
• the wall is perfectly level
• there are no obstructions nearby that could compromise
the inlet and outlet airflow
• the wall on which you are installing the unit is (if possible)
an external perimeter wall, in order to allow condensate
drain outside the premises
• air flow is not directed towards by-standers
2�2 Installation mode
The assembly steps described below and their drawings refer
to a version of the machine with connections on the right
side.
For ideal installation and performance levels, carefully fol-
low the instructions in the manual.
Failure to do so may cause system malfunctions and auto-
matically voids the warranty, and relieves the constructor
of any harm caused to person, animals o property.
2�3 Installation minimum distances
The figure shows the minimum distances required of the fan-
coil from the walls and furniture on site.
20 mm
20 mm
120 mm