28
TOUCHPAD AND REMOTE CONTROL
3�3 Warnings
Visualization of alarms on display
In the event of a malfunction, the display shows an alarm
code.
In the event of an alarm, the device still maintains active
functions.
E1
Room temperature probe (RT) failure
It is possible to normally activate the Cooling, Dehu-
midification and Heating modes.
E2
Internal battery probe IPT failure
It is possible to normally activate the Cooling, Dehu-
midification and Heating modes.
E5
Indoor fan motor failure
You cannot activate any operating mode
E7
Lack of communication with the display
You cannot activate any operating mode
CP Presence contact CP open
The unit is enabled only if the contact is closed,
check the connection of the terminals
lampeggiante
Incorrect water temperature
In heating mode, the water temperature is below 30
°C
lampeggiante
Incorrect water temperature
In cooling mode, the water temperature is above 20
°C
Operating the unit if the remote control is not available
If you lose the remote control, the batteries run out or the
remote stops working, you can be operate the device with
the keys on the touch-screen display on-board the machine.
Troubleshooting
For the user it is important to distinguish any malfunction or
performance levels that differ from the system’s standard op-
erating values (see technical specifications). The most com-
mon problems can be easily solved by the user by perform-
ing certain simple tasks (see the Troubleshooting paragraph),
while some system alarms require that you contact the Tech-
nical Customer Service.
Please keep in mind that any attempt by unauthorised
staff to repair the device automatically voids any form of
warranty.