TOUCHPAD AND REMOTE CONTROL
Cooling only mode
To select the Cooling operation
–
press the
key for about 2 seconds
The symbol
on indicate the Cooling function enable
When this operating mode is enabled, the device dehumid-
ifies and cools the room. With setpoint lower than the room
temperature, the fancoil starts and starts supplying cold air,
keeping ventilation active even if the setpoint is reached.
Ventilation only mode
To select the Ventilation operation
–
press the
key for about 2 seconds
The symbol
on indicate the Ventilation function enable
When you enable this function, the device enable the fan
and does not adjust the temperature or the humidity of the
air in the room.
Set the speed
To select the fan speed control
–
press the key
The
symbol varies according to the ventilation speed with the following sequence:
Minimum
Medium
Maximum
Automatic (you will notice the 3 speed bars slide on the display)
The higher the set speed, the higher the device’s perfor-
mance (but also the louder the noise).
If you set the speed to Automatic the micro-processor will
adjust the speed automatically (the higher the difference
between the room temperature and the set temperature,
the higher the speed). The speed is reduced automatically
as the room temperature gradually reaches the set tem-
perature.
In dehumidification only mode and night comfort mode,
you cannot adjust the speed, as the unit can work only at
low speed.
Heating only mode
To select the Heating operation
–
press the
key for about 2 seconds
The symbol
on indicates the Heating function enable
When this operating mode is enabled, the device heats the
room. With setpoint higher than the room temperature, the
fan coil starts and starts supplying hot air.
Night function
To select the Night comfort function
–
press the
key for about 2 seconds
The symbol
on indicate the Night comfort function enable
In this mode the fan is set to minimum speed.
The set temperature changes automatically:
• in heating function decreases by 1 °C after one hour and
by another degree after 2 hours
• in cooling function decreases by 1 °C after one hour and
by another degree after 2 hours
• In both cases after the second hour the setting of the tem-
perature set is not further altered and after 6 hours the
appliance is put on stand-by
This function is not available in the dehumidification only
and ventilation only.
This function can be excluded at any time by pressing the
button further.
If you simultaneously set the Timer function, the device
switches off after the preset time.
Содержание Filomuro SLW 400
Страница 1: ...EN Installation and user manual SLW...
Страница 40: ...40 Troubleshooting NOTE...
Страница 41: ...41 Troubleshooting NOTE...
Страница 42: ...42 Troubleshooting NOTE...
Страница 43: ...43 Troubleshooting NOTE...