 MAINTENANCE

   

 MAINTENANCE

6�1    Routine  maintenance

Routine maintenance is essential to keep the device always 
efficient, safe and reliable over time.
It can be done:

•  every six months

Before each cleaning and maintenance intervention:

–  disconnect the device from the power mains by turning 

the system master switch to "OFF"

Wait for the components to cool down in order to avoid 

any burns.

After completing the maintenance work, must be restored 
the original condition.

It is forbidden to open the access doors and carry out 
any technical or cleaning intervention, before having dis-
connect the device from the mains supply by placing the 
main switch of the system on "OFF".

Warnings:

•  Do not lean or sit on the fancoil to avoid damaging the 

appliance.

•  Do not manually move the horizontal louver of the air out-

let. Always use the remote control to do this operation.

•  If water leaks from the device, you must switch it off im-

mediately and disconnect the power supply. Then, call the 
nearest customer service centre.

•  The device must not be installed in rooms where there are 

explosive gases or where there are conditions of humidity 
and temperature out of the limits defined in the installa-
tion manual.

•  Clean the filter regularly.

 Six-monthly  operations

   

 External  cleaning

Clean the external surfaces using a soft cloth dampened with 
water.

Do not use abrasive sponges or abrasive or corrosive de-
tergents as you might damage the painted surface.

   

 Air  intake  filter  cleaning

Cleaning the filter must be carried out: 

•  after prolonged operation, considered the concentration 

of impurities in the air,

•  when you plan to restart the system after prolungate dis-

use.

Содержание Filomuro SLW 400

Страница 1: ...EN Installation and user manual SLW...

Страница 2: ...use of the machine in a rapid unmistakable way Editorial pictograms User Refers to pages containing instructions or information for the user Installer Refers to pages containing instructions or inform...

Страница 3: ...rain 14 2 9 Filling the system 15 2 10 Electric connections 15 2 11 Diagrams and configurations electrical controls 17 3 Touchpad and remote control 24 3 1 Interface 24 3 2 Main functions 25 3 3 Warni...

Страница 4: ...ost download a copy from the website All repair or maintenance interventions must be per formed by the technical service department or by pro fessionally qualified personnel as foreseen in this bookle...

Страница 5: ...al specifications 2 pipes Technical data DC Models m u 400 600 800 Battery water content L 0 50 0 61 0 77 Maximum working pressure bar 10 10 10 Maximum water inlet temperature C 80 80 80 Minimum water...

Страница 6: ...during transportation Filomuro Filomuro Filomuro Models m u 400 600 800 Dimensions and weight during transportation Total length mm 1020 1220 1302 Total height mm 490 490 490 Total depth mm 213 213 21...

Страница 7: ...all surface is not crossed by pipelines or power lines the wall is perfectly level there are no obstructions nearby that could compromise the inlet and outlet airflow the wall on which you are install...

Страница 8: ...A lift the filter slightly rotate until the complete exit from the housing A Filter B Extraction direction A B remove the filter Removal of the aesthetic front panel A side panels B aesthetic front pa...

Страница 9: ...stalled later leave the connecting pipes plentiful so as not to make joints A built in cistern B connecting water pipelines C condensation drainage pipe A B C 2 6 Installation use the paper template s...

Страница 10: ...en support wall use a leveler check the inclination towards the attachment side fix the screws assemble the unit check correct attachment to the bracket G check the inclination towards the attachment...

Страница 11: ...r choosing the right water lines and their size in accordance with good installation practices and the applicable law Keep in mind that undersized pipelines lead to poor sys tem operation Position and...

Страница 12: ...ly check that the insulation is tight in order to pre vent the formation and dripping of condensate Hydraulic accessories The device comes standard without any shut off valve In other case depending o...

Страница 13: ...ting for water inlet pipe D water outlet pipe fitting E electrical cable entry hole A D E B C Connection with 3 way diverting valve unit with thermoelectric actuator V30688 In case of choice for the 3...

Страница 14: ...A Filomuro B liquid drain pipe A B provide a slope never less than 1 insulate fitting points Pay attention to the tilt of the condensate drain pipe Make the condensate liquid flow directly onto a gut...

Страница 15: ...etwork are adapted to the absorption of the apparatus considering also any oth er devices in parallel operation the power supply voltage and system frequency match to the values indicated on the devic...

Страница 16: ...iring diagram of the unit you are installing You can use a cable embedded in the wall in the position traced with the installation template to make the electrical connection recommended connection for...

Страница 17: ...n the supply H2 Water temperature probe M1 Fan motor DC Inverter EV Hot water solenoid valve 230 V 50 Hz 1 A power output L N 230 V 50 Hz electrical power supply connection G Protective conductor CP P...

Страница 18: ...spect the AB polarization H2 Hot water temperature probe 10 k M1 Fan motor DC Inverter Y1 Water solenoid valve 230 V 50 Hz 1 A power output L N 230 V 50 Hz electrical power supply connection BO Boiler...

Страница 19: ...t the cables unscrew the corresponding screw with a screwdriver remove the conductor When the CP contact opens connected to a clean contact not live the unit is in stand by The display reads CP Error...

Страница 20: ...inimum fan speed 680 rpm V4 Super silent speed 400 rpm E Heating cooling selection input Y1 Water solenoid valve 230 V 50 Hz 1 A power output M1 Fan motor DC Inverter TA 3 speed room thermostat to buy...

Страница 21: ...nds provided with water probe the on board H2 probe will not be connected the device will be controlled from the remote command If this is not the case connect the 10 k probe located inside the batter...

Страница 22: ...suffix 0V00 Printed circuit board BB0699 The PCB is included in the supply L N 230 V 50 Hz electrical power supply 10V Device pilot input 0 10 V Input impedance 25 k Y1 Water solenoid valve 230 V 50...

Страница 23: ...value 1400 rmp for voltage values 1 1 V 10 V DC The solenoid valve Y1 is enabled by voltage values 1 V DC turns off with values 0 9 V DC Error signals LED signals LED off The input signal is below 0...

Страница 24: ...andle with care avoiding strong impacts or falling on hard surfaces Do not placing obstacles between the remote control and the device while you are using the remote Important If other devices are bei...

Страница 25: ...e device can help you locate the switch or introduce a power plug on the device plugging it into the system s socket After you perform these steps you can operate the system either by pressing the sym...

Страница 26: ...he set temperature the higher the speed The speed is reduced automatically as the room temperature gradually reaches the set tem perature In dehumidification only mode and night comfort mode you canno...

Страница 27: ...ed with the automatic switching on of the appliance press again the key to confirm the setting To program the stand by of the appliance press the key for 5 seconds The symbol on indicates the Timer fu...

Страница 28: ...ante Incorrect water temperature In heating mode the water temperature is below 30 C lampeggiante Incorrect water temperature In cooling mode the water temperature is above 20 C Operating the unit if...

Страница 29: ...remoted in one of the fan coils connected to it Mounting The wall mounted remote control must be installed on internal walls at a height of about 1 5 m from the floor away from doors or windows away f...

Страница 30: ...electric wires through the hole provided fix the base of the control to the wall using suitable screw and plugs perform the electrical connection close the control Pay attention not to crush the cond...

Страница 31: ...ence sensor enabling badge remote change of season Function When the contact connected to the CP input is closed all the users connected will be switched off At the touch of a button on the display th...

Страница 32: ...y Supervision on Flashing with CP closed contact Switched on for alarm indication Resistance enabled indication Cooling function on Heating function on Remote control indication off Automatic function...

Страница 33: ...change The adjustment range goes from 16 to 28 C with a reso lution of 0 5 C Out of range values from 5 C and 40 C are allowed ex cept in automatic mode These value should be set only for short perio...

Страница 34: ...use On the display will appear only the room temperature Deactivation To deactivate the display press the key for about 2 seconds All the light signals go off In stand by mode the control ensure an a...

Страница 35: ...ol WALL MOUNTED CONTROL B3V151 B3V152 5 1 Electric connections Connection diagram B3V151 1 PCB 2 Wall control H4 H2 S1 N276660C DATA I O LED H4 H2 2 1 B3V152 1 PCB 2 Built in wall control H4 H2 S1 N27...

Страница 36: ...amaging the appliance Do not manually move the horizontal louver of the air out let Always use the remote control to do this operation If water leaks from the device you must switch it off im mediatel...

Страница 37: ...er B A wash the filter with running water allow it dry Do not use detergents or solvents to clean the filter Inserting the filter Remount the filter paying particular attention to introduce the lower...

Страница 38: ...t energy sav ing keep the filters clean keep the doors and windows of the locations fitted with air conditioning systems closed as much as possible During summer limit the entry of direct sun rays int...

Страница 39: ...you were to turn on the problem may be in the electronic control The ventilation motor is jammed or burnt Check the motor windings and check if the fan rotates freely The wirings are not correct Chec...

Страница 40: ...40 Troubleshooting NOTE...

Страница 41: ...41 Troubleshooting NOTE...

Страница 42: ...42 Troubleshooting NOTE...

Страница 43: ...43 Troubleshooting NOTE...

Страница 44: ...realized by Innova technical dept INNOVA S r l Via I Maggio 8 38089 Storo TN ITALY tel 39 0465 670104 fax 39 0465 674965 info innovaenergie com N273110A Rev 06...

Отзывы: