TOUCHPAD AND REMOTE CONTROL
To activate the device
–
press the
key
he symbol
lights up
4�4 Main functions
Operating mode set-up
to switch the operating mode
–
press the
key for about 2 seconds
The symbol
on indicates the Heating function enable
The symbol
on indicate the Cooling function enable
In heating function the symbols is alight with setpoint
higher than the room temperature.
In cooling function the symbols is alight with setpoint
lower than the room temperature.
When the setpoint is incorrect both symbols are switched
off.
Put in stand-by the control
To put in stand-by the control
–
press the
key for about 2 seconds
The control goes out
In stand-by mode the control ensures an antifreeze safety.
In case of temperature <5 °C, the hot water solenoid valve
outputs and boiler consent are activated automatically.
Set room temperature
To set-up the temperature
–
operate the
keys to decrease or increase the desired value
The displayed value change
The adjustment range goes from 16 to 28 °C, with a reso-
lution of 0,5 °C.
Out of range values from 5 °C and 40 °C are allowed, ex-
cept in automatic mode. These value should be set only
for short periods of time.
Automatic operation
To select the Automatic function
–
press the
key for about 2 seconds
The symbol
on indicates the Automatic function enable
The ventilation speed is automatically adjusted between
a minimum value and a maximum value based on an al-
gorithm type PI, according to the actual distance from the
room temperature set-point.
Silent operation
To select the Silent operation
–
press the
key for about 2 seconds
The symbol
on indicates the Silent function enable
The ventilation speed is limited at a more reduced maxi-
mum value.
Night function
To select the Night function
–
press the
key for about 2 seconds
The symbol
on indicate the Night function enable
The ventilation speed is limited at a very low value.
The set temperature changes automatically:
• in heating function decreases by 1 °C after one hour and
by another degree after 2 hours
• in cooling function decreases by 1 °C after one hour and
by another degree after 2 hours