Inner Range Inception Security Controller
Installation Manual. Rev. 4.0
© 2016 - 2020. Inner Range Pty Ltd.
10
www.innerrange.com
LED Status Indicators
The Inception controller has 11 status LED’s to quickly identify the current operational status.
LED
LED State
Meaning
POWER
OFF
No DC IN connected. (Mains not present)
ON Green
DC IN connected (Mains power present)
and within nominal voltage range.
Flash 2 Seconds (80% duty cycle) Battery is present and in nominal voltage
range, and battery test is in progress.
Flash 0.4 Second (50% duty cycle) DC IN is outside nominal voltage range (too
high or too low)
Flash 1 second (10% duty cycle)
Internal problem. Return for repair.
BATTERY
OFF
No battery connected.
ON Green
Battery connected, within nominal voltage
range and no battery test in progress.
Flash 2 Seconds (80% duty cycle) Battery is present and in nominal voltage
range, and battery test is in progress.
Flash 0.4 Second (50% duty cycle) Battery is outside nominal voltage range
(too high or too low)
Flash 1 second (10% duty cycle)
Internal problem. Return for repair.
SYSTEM
Flashing Green
Inception controller is running.
ON Red
One or more of the power supply outputs
(VOUT) is shorted. Note that the green
LED remains flashing which results in an
alternating red & orange pattern.
SKYTUNNEL
ON Green
SkyTunnel connection is established.
ETHERNET
ON Green
An Ethernet cable is connected and
Inception has an IP address.
ALARMS
ON Red
There are one or more Alarms in the queue
to be sent to a monitoring station.
WIFI
OFF
No Wi-Fi module present, or Inception not
configured to use Wi-Fi.
ON Green
Wi-Fi module present, and Inception is on
Hotspot (Access point) mode.
Or, Wi-Fi module present, and Inception is
connected to a local Wi-Fi network.
Flashing Green
Wi-Fi module present. Inception unable to
connect to a local Wi-Fi network.
OUT 1
ON Green
OUT 1 is On (i.e. COM & NO connected)
OUT 2
ON Green
OUT 2 is On
OUT 3
ON Green
OUT 3 is On
OUT 4
ON Green
OUT 4 is On