USB Port. 

 

Inception Wireless Adapter 

An optional Inception Wireless Adapter can be purchased to provide a convenient wireless 
connection option with two modes of operation: 

  In Access Point mode, the Wi-Fi adapter can act as a wireless access point allowing 

installers to establish a temporary wireless connection directly to the Inception controller. 

  In Client mode the Wi-Fi adapter can provide Inception with a permanent connection to an 

existing Wi-Fi network.  A magnetic antenna base & extension cable that can be mounted 
on the outside of the enclosure is included for this purpose. 

 
By default, access point mode is enabled to aid with initial connection and maintenance.  The 
Wireless Adapter is connected to the USB Port.  Once connected, wait for the 

‘WIFI’ LED to turn 

on then you can use your Wi-Fi enabled device to connect to the network.  
By default, the name of the Wi-Fi network will be the Inception controller serial number (e.g. 
WS001923) with the password “inception”.  Open a browser and navigate to the URL 

http://inception.local

  

See the Quickstart Guide for more information.

 

 

Alarm Communicator 

An optional T4000 Multipath-IP Alarm Communicator or other supported 3

rd

 party alarm 

communicator (depending on your region) may be connected to the USB port. 

See the 

‘Alarm Reporting’ section of this manual for details. 

 

Inception USB Mini-Hub 

If you need to connect more than one device to the USB Port, (e.g. Both of the devices listed 
above) an Inception LAN Hub may be purchased to provide up to 4 powered USB Ports. 
The LAN Hub is powered from the Inception controller 

‘VOUT’ or from a separate battery-backed 

12V power supply.  e.g. Integriti 3A Power Supply.  

NOTE:

  

If ‘VOUT’ is used, then the same 

‘VOUT’ connector should not be used to power any device outside the enclosure. 
 

 
 

 

 

Содержание 996300

Страница 1: ...0 2016 2020 Inner Range Pty Ltd 1 www innerrange com Inception Controller by Inner Range P N 996300 V4 Installation Manual Current to Firmware V4 0 and Controller PCB Rev E BEFORE COMMENCING INSTALLA...

Страница 2: ...ED Status Indicators 10 WIRING DIAGRAMS 11 Power Supply 11 Output Relays OUT1 4 11 Zone Inputs 12 Tamper Input 12 LAN Reader Ports 13 LAN and Reader Installation Diagrams 14 USB Port 16 Inception Wire...

Страница 3: ...n type siren speakers are provided on 8 Zone LAN Expander Modules 4 End of line EOL Resistors The inputs on the Inception controller and expansion modules utilize dual end of line resistors The defaul...

Страница 4: ...12V DC power outputs for powering external security devices LAN port for system expansion via RS 485 Reader port for connection of up to 8 x Inner Range SIFER or SIFER Keypad readers DC power input f...

Страница 5: ...ior to V2 0 0 only supports 32 Doors and 2000 Users Inception Firmware prior to V3 1 1 only supports 50 000 Events Inception Firmware prior to V4 0 only supports 32 Areas 256 Wiegand readers In Out Re...

Страница 6: ...See Specifications section RS485 LAN Reader Surge Diverter 995041 N A Integriti 3A battery backed Power Supply 996091 N A Integriti 8A battery backed Power Supply 996092 N A Replacement Power Supply A...

Страница 7: ...d party battery backed security system power supply DC IN must not be used Ensure that the power requirements do not exceed the power supply s current limit Remember to allow for the current required...

Страница 8: ...ce Mode from the Dashboard or System Menu Select Disable Service Mode If required choose a Delay Before Disable period Click on Disable Logon Press MENU 7 1 Press OFF Wireless Devices Inception suppor...

Страница 9: ...r LEDs will light in sequence When this boot sequence is complete the SYSTEM LED will flash green to indicate the controller is running The other LEDs will indicate the current state condition of thei...

Страница 10: ...ry test is in progress Flash 0 4 Second 50 duty cycle Battery is outside nominal voltage range too high or too low Flash 1 second 10 duty cycle Internal problem Return for repair SYSTEM Flashing Green...

Страница 11: ...pply is recommended to power inductive loads to protect the controller provide longer battery backup minimise the possibility of earth loops Non Inductive Loads e g 12V Sounder Beeper Strobe LED etc T...

Страница 12: ...ow A different configuration may be selected Current options are 1k 1k Seal 1k Alarm 2k 6k8 3k3 Seal 6k8 Alarm 10k1 4k7 4k7 or 4k7 2k2 Seal 4k7 Alarm 9k4 or 6k9 10k 10k Seal 10k Alarm 20k Example PIR...

Страница 13: ...website for details See Additional Resources at the rear of this manual Additional installation requirements for the LAN port A The LAN connection used to power LCD Terminals etc can be derived from...

Страница 14: ...AN and Reader Installation Diagrams The installation requirements are illustrated in the drawings below and on the following page The characters in square brackets reference the various points in the...

Страница 15: ...15 www innerrange com SIFER or SIFER Keypad Reader wiring detail SIFER or SIFER Keypad Reader connection overview 6 Shielded twin twisted pair data cable II III 2 I Any Reader more than 100m from the...

Страница 16: ...ort Once connected wait for the WIFI LED to turn on then you can use your Wi Fi enabled device to connect to the network By default the name of the Wi Fi network will be the Inception controller seria...

Страница 17: ...ation occurs successfully in the absence of alarm events Inception supports both of these reporting paths at the same time to provide redundancy You will need to select a plan based on your preferred...

Страница 18: ...gured alarm reporting paths are incorrect Alarm events cannot be sent via a network path to the monitoring station Ensure a monitoring station account is configured for this device If reporting via Sk...

Страница 19: ...ge In order to set the time manually click Set Date Time Manually Once the dialog box appears either set the time using the calendar or by clicking the Get time from browser This will sync the incepti...

Страница 20: ...Firmware update The Inception controller and LAN Modules can be updated to the latest firmware version from the browser Use the Update Controller or Update Modules selections in the Firmware Update op...

Страница 21: ...tings and programming are restored to the factory default including installer codes and logins Single beep at start and higher pitched beep at end of 5s button press Press 5 times in less than 5 secon...

Страница 22: ...pter Inception 4 Port USB Hub 25mA per relay 33mA when Controller powered from BATT i p 25mA 40mA when Controller powered from BATT i p 20mA 40mA when Controller powered from BATT input Not including...

Страница 23: ...See the Parts Accessories Lists in this manual for details of power supply current requirements of the accessories and expansion modules that may be powered from the Inception controller power supply...

Страница 24: ...d Installation manuals Integriti SIFER Smart Card Reader SIFER Keypad Installation manuals Integriti Expansion Module installation manuals SLAM 8 Zone Exp RF Exp etc Integriti Power Supply installatio...

Отзывы: