Using the device
17
Installation and programming manual
Removal of the jumper from the earth fault signalling connector (
table 6, E
)
deactivates the earth fault check.
The
T7
output signals a fault relating to the
AUXx
power output with grade 3
security rating caused by the intervention of the protection circuit it is equipped
with. Activation can occur in the event of:
•
Overvoltage on the power output
•
Short-circuit on the power output
•
Overload on the power output
The
T8
output signals a fault relating to the
AUXx
power output with grade 3
security rating caused by a fault on the power supply unit. Activation can occur in
the event of:
•
Overload on the power supply unit
•
Overheating on the power supply unit
The
T9
output signals a fault relating to the
AUXx
power output with grade 3
security rating caused by communication problems between the station boards.
Activation can occur in the event of:
•
Loss of communication between the SmartLevel motherboard and the
LIVPWR100 board
•
Loss of communication between the LIVPWR100 board and the power supply
unit
The
T10
outputs signals a fault caused by the total loss of operating capacity of
the SmartLevel motherboard.
4-5
Connection to intrusion
control systems
Compliance with standard EN50131-6 grade 3 provides the following
programming directions for intrusion control-panel terminals which are connected
to the signalling outputs of the SmartLevel power-supply station:
Table 7: Programming of the signals to the control panel
SmartLevel
output
Control panel input terminal
Type
Option
Description
Relay
24 hour Zone
/
G3 station tamper
OC1
Instant Zone
Fault zone
G3 station mains
fault
OC2
Instant Zone
Fault zone
G3 station battery
fault
T6
Instant Zone
Fault zone
Earth dispersion
T7
Instant Zone
Fault zone
G3 power output
fault
T8
Instant Zone
Fault zone
G3 station power
supply fault
T9
Instant Zone
Fault zone
G3 station
monitoring fault
T10
Instant Zone
Fault zone
G3 station main
PCB fault