Using the device
Power supply stations
The jumpers on the isolator board [
A
] must be cut.
4-2
Relay Output
The output relay (terminals
NC
,
NO
and
COM
) provides a contact capable of
switching a 30V 1A maximum load.
The relay is normally active during standby status and maintains the COM contact
closed to NC. In the event of tamper on the device enclosure (forced opening or
dislodgement) the relay will close COM to NO.
The COM contact will close back to NC when the tamper event ceases.
4-3
OC1 and OC2
The
OC1
and
OC2
terminals are both open-collector outputs. When the output
activates, its terminal is floating. During standby status, the terminal closes to
ground.
The OC1 output activates in the event of mains failure (primary power source).
The OC2 output activates in the event of battery trouble (disconnected or
inefficient).
Both outputs reset to standby (closed to ground) when their respective activation
causes cease.
4-4
Tx terminal outputs
The
T6
,
T7
,
T8
,
T9
and
T10
outputs are open-collector outputs.
When activated, the terminal is connected to the 13.8 V internal power-supply of
the board by means of an 18kOhm pull-up resistor. During standby status, the
terminal closes to ground.
The
T6
output signals a fault relating to the dispersion to earth of the current in
some point the system.
A
SmartLiving
control
panel
SmartLevel
power-
supply
station
I-BUS
isolator
IB100