HandPunch 3000/4000 Manual
55
The Calibrate command displays the HandPunch’s exposure values, allowing
you to verify these values are within normal operating parameters. The
standard operating parameters are shown in Table 8.
Table 8: Normal Operating Parameters
Parameter
Normal Range
Row “r”
0 +/- 2
Column “c”
0 +/- 2
Exposure “e”
100 +/- 20
The status display command allows you to enable or disable the displaying of
the following information.
•
the status values of HandPunch inputs and outputs
•
the hand read score of the last user to verify on the system
When the status display is enabled, Figure 8-1 identifies each status display
field value.
Status Display
Calibrate
Last Hand Read Score
Aux Out 2
Aux Out 1
* Aux Out 0
* Lock
Aux In 2
Request to Exit
Aux In 1
Door Monitor Switch
Tamper
* These status values are inactive if the
reader is in Card Reader Output Mode.
O = Circuit Open H = Output is OFF (High)
C = Circuit Closed L = Output is ON (Low)
O C O C O H L H L NN
- ENTER ID -
O C O C O H L H L NN
Figure 8-1: Status Display Chart
Содержание SCHLAGE HP-3000
Страница 1: ...Terminal User s Guide HP 3000 4000...
Страница 12: ...Introduction 10 This page is intentionally blank...
Страница 24: ...Planning An Installation 22 This page is intentionally blank...
Страница 32: ...Networking and Communications 30 This page is intentionally blank...
Страница 44: ...Wiring Connections 42 This page is intentionally blank...
Страница 46: ...Planning an Installation 44 This page intentionally blank...
Страница 48: ...Planning an Installation 46 This page intentionally blank...
Страница 52: ...Enter a Command Menu 50 This page is intentionally blank...