44
MODULATE CONTROL VALVE ADJUSTMENT
Ensure that the compressor is isolated from the compressed air system by closing the isolation valve and
venting pressure from the drip leg. Ensure that the main power disconnect switch is locked open and tagged.
1. Put the compressor in the MODULATION mode.
2. Connect a pressure gauge to outlet port of modulation valve with 1/4” tubing tee.
3. Loosen the adjustment screw locknut and back out adjusting screw 3 turns. See Figure 2
4. Put the main power disconnect switch in the ON position.
5. Open the isolation valve and start the compressor.
6. Adjust the isolation valve to bring the discharge air pressure to the rated discharge pressure (100, 125, or
140 psig).
7. While maintaining the rated discharge pressure, turn the adjustment screw on the modulation valve (see
Figure 2) so that the test pressure gauge reads:30 psig for modulate 60% capacity Tighten the adjustment
screw locknut.
8. Press UNLOADED STOP. Wait for sump pressure to go 0 psig.
Close the isolation valve or vent off all system air.
9. Put the compressor in the desired control mode.
10.Remove the test pressure gauge and replace 1/4” plastic plug.
Table 12
Содержание R110IU-10
Страница 5: ...5 S3 Intellisys Controller Operating Instructions...
Страница 6: ...6 Software Navigation...
Страница 7: ...7 Eiger Controller Fault Indicators 020 Tr Motor PTC Open High Motor Temperature...
Страница 14: ...14 Star Delta Wiring Diagram...
Страница 15: ...15...
Страница 16: ...16 Soft Start Wiring Diagram...
Страница 17: ...17...
Страница 18: ...18 Line Start Schematic...
Страница 19: ...19...
Страница 20: ...20 Process and Instrumentation Diagram...
Страница 21: ...21...
Страница 28: ...28 Maintenance...
Страница 29: ...29 Maintenance...
Страница 30: ...30 Maintenance...
Страница 31: ...31 S3 Controller Input Output Overview AI Analog Input DI Digital Input DO Digital Output...
Страница 45: ...45 Standard S3 Menu Structure and Parameters Table 12...
Страница 46: ...46 Standard S3 Menu Structure and Parameters Table 12...
Страница 47: ...47 Standard S3 Menu Structure and Parameters Table 12...
Страница 49: ...49 Modbus Register Listing...
Страница 50: ...50 Table 13 Modbus Register Listing...
Страница 52: ...52 Appendix 1 Thermistor 2ATT 34 to 124 C 255 F Air end Discharge...
Страница 53: ...53...
Страница 54: ...54...
Страница 55: ...55...
Страница 56: ...56...
Страница 57: ...57...
Страница 58: ...58 General Specifications for Eiger Packages...
Страница 59: ...59...
Страница 60: ...60...
Страница 61: ...61...
Страница 62: ...62...
Страница 63: ...63...
Страница 64: ...64...
Страница 65: ...65...
Страница 66: ...66...
Страница 67: ...67...
Страница 68: ...68...
Страница 69: ...69...
Страница 70: ...70...
Страница 71: ...71...
Страница 72: ...72...
Страница 73: ...73...
Страница 74: ...74...
Страница 75: ...75...
Страница 76: ...76...
Страница 77: ...77...
Страница 78: ...78...
Страница 79: ...79...