11.0 FAULT FINDING
IRN37–160K–CC & IRN50–200H–CC & IRN75–160K–2S & IRN100–200H–2S
76
SYMPTOM
FAULT
REMEDY
Compressor will not
meet pressure required
by system
Compressor not sized to meet
system requirements or
requirements have been
changed.
Contact your local IR representative
Air loss due to pipe, hose, joint
or seal failure
Overhaul or replace
Air loss due to blowdown valve
stuck open
Overhaul or replace
Air loss through pressure relief
valve not seating or set
incorrectly
Overhaul or replace
Air loss due to moisture
separator drain trap stuck open
Overhaul or replace
Motor speed too low caused by
drive incorrectly set
Contact your local IR representative
Motor speed too low caused by
fault in drive settings
See section on drive faults
Intellysis controller fault
Overhaul or replace
Drive motor fault
See section on drive faults
Pressure transducer faulty,
incorrectly calibrated or EMF
interference
Recalibrate or replace
Incorrect Intellisys controller
settings
Check and modify settings
Inlet grill or ducting is blocked
Check and clean
Air filter dirty or collapsed
Replace
Inlet valve not opening fully
Overhaul or replace
Separator element dirty or
collapsed
Replace
Pipe / Hoses blocked or
collapsed
Clean or replace
Cooler core blocked
Clean or replace
Minimum pressure check valve
not functioning correctly
Overhaul or replace
Equipment between compressor
and customer measuring point
causing pressure drop /
pressure loss
Review system requirements