8.0 GENERAL INFORMATION
IRN37–160K–CC & IRN50–200H–CC & IRN75–160K–2S & IRN100–200H–2S
35
8.1 TECHNICAL INFORMATION – TWO STAGE
N75K
N90K
N110K
N100H
N125H
N150H
General
Sound pressure level dB(A) *
75
75
75
75
75
75
Maximum ambient temperature
_
C (
_
F)
46 (115)
46 (115)
46 (115)
46 (115)
46 (115)
46 (115)
Minimum ambient temperature
_
C (
_
F)
1.7 (35)
1.7 (35)
1.7 (35)
1.7 (35)
1.7 (35)
1.7 (35)
Weight Kg (lbs)
3650
(8030)
3650
(8030)
3650
(8030)
3650
(8030)
3650
(8030)
3650
(8030)
Maximum pressure barg (psig)
10 (145)
10 (145)
10 (145)
10 (145)
10 (145)
10 (145)
Minimum pressure barg (psig)
4.5 (65)
4.5 (65)
4.5 (65)
4.5 (65)
4.5 (65)
4.5 (65)
Coolant capacity litres (US gal)
90 (24)
90 (24)
90 (24)
90 (24)
90 (24)
90 (24)
HAT switch setting
_
C (
_
F)
120
(248)
120
(248)
120
(248)
120
(248)
120
(248)
120
(248)
Performance
**
Flow at 7.5 Barg (m
3
/min)
15.7
18.0
22.1
–
–
–
Flow at 8.5 Barg (m
3
/min)
14.2
17.5
20.4
–
–
–
Flow at 10 Barg (m
3
/min)
13.1
15.4
18.9
–
–
–
Flow at 14 Barg (m
3
/min)
–
12.5
15.4
–
–
–
Flow at 100 psig (cfm)
–
–
–
560
690
825
Flow at 125 psig (cfm)
–
–
–
504
621
743
Flow at 140 psig (cfm)
–
–
–
470
580
693
Flow at 200 psig (cfm)
–
–
–
–
443
548
Air Cooling System
Cooling air flow m
3
/min (cfm)
382
(13500)
382
(13500)
382
(13500)
382
(13500)
382
(13500)
382
(13500)
Maximum
∆
P in air ducts Pa (inch WG)
124 (0.5)
124 (0.5)
124 (0.5)
124 (0.5)
124 (0.5)
124 (0.5)
Compressed air outlet
∆
T
_
C (
_
F)
8 (15)
8 (15)
8 (15)
8 (15)
8 (15)
8 (15)
* In accordance with PNEUROP PN8NTC2.3
** Tolerances in accordance with ISO 1217
*** Always apply local electrical codes for sizing cables and fusing. In the abscence of local codes the minimum
cable size should be calculated on basis of mean package full load current X1.25 (i.e. 25% margin)