23
INSTALLATION AND MAINTENANCE
LSA 46.2 / 47.1
ALTERNATORS
SPARE PARTS
Ref. 2981 GB - 4.33/a - 04.00
LEROY-SOMER
5 - SPARE PARTS
5.1 - First maintenance parts
Emergency repair kits are available as an option.
They contain the following items :
5.2 - Technical support service
Our technical support service will be pleased to provide any
additional information you may require.
When ordering spare parts, you should indicate the complete
machine type, its serial number and the information given on
the nameplate.
Address your enquiry to your usual contact.
Part numbers should be identified from the exploded views
and their description from the parts list.
Our extensive network of service centres can dispatch the
necessary parts without delay.
To ensure correct operation and the safety of our machines,
we recommend the use of original manufacturer spare parts.
In the event of failure to comply with this advice, the
manufacturer cannot be held responsible for any damage.
5.3 - Accessories
5.3.1 - Space heater for use when stopped
The space heater must start up as soon as the alternator
stops. It is installed at the rear of the machine. Its standard
power is 250W with 220V or 250W with 110V on request.
Warning : the power supply is present when the
machine has stopped.
5.3.2 - Stator thermistor temperature probes
(PTC)
These are thermistor triplets with a positive temperature
coefficient installed in the stator winding (1 per phase). There
can be a maximum of 2 triplets in the windings (at 2 levels :
warning and trip) and 1 or 2 thermistors in the shields.
These probes must be linked to appropriate detection relays
(supplied optionally)
Cold resistance of thermistor probes:
100 to 250
Ω
per probe.
5.3.3 - Connection accessories
- 6-wire machines
Requirements for coupling (F) :
- 3 flexible shunts
- 12-wire machines
Requirements for coupling (A) :
- 6 links
- 1 link for the neutral
Requirements for coupling (F.F) :
- 4 flexible shunts
- 2 flexible shunts
- 1 link for the central point
- 1 additional starting range
- 1 additional terminal
Requirements for coupling (F) :
- 3 flexible shunts
- 1 link for the central point
Ref.
Description
Qty
LSA 46.2
Part ref
Emergency kit
1
198 AVR
1
R 448
ESC 220 CV019
343 Diode bridge assembly
1
LSA 471. 9. 07
LSA 471.9 /
0.08
ADE 461 EQ 004
347 Surge suppressor
1
LSA 461.9.01
CII 111 PM 005
AVR fuse
2
250 V - 10 A
PEL 010 FG 008
Other spare parts
60
DE bearing
1
6316 2RS/C3
RLT 080 TS030
70
NDE bearing
1
6315 2RS/C3
RLT 075 TS030
Ref.
Description
Qty
LSA 47.1
Part ref
Emergency kit
1
198 AVR
1
R 448
ESC 220 CV019
343 Diode bridge assembly
1
LSA 471. 9. 07
LSA 471,90.08
ADE 471 EQ 007
347 Surge suppressor
1
LSA 461.9.01
CII 111 PM 005
AVR fuse
2
250 V - 10 A
PEL 010 FG 008
Other spare parts
60
DE bearing
1
6318 2RS/C3
RLT 090 TS030
70
NDE bearing
1
6315 2RS/C3
RLT 075 TS030
Содержание G 270
Страница 2: ......
Страница 17: ...Alternator 15...
Страница 28: ......
Страница 29: ......
Страница 30: ......
Страница 31: ...User s manual Ingersoll Rand Control unit Intellisys Level 1 1 06F R f constructeur R f GPAO 33502013801...
Страница 57: ......
Страница 58: ......
Страница 121: ......
Страница 122: ...7739614 1 English 04 2002...
Страница 123: ......
Страница 124: ......
Страница 125: ...EDITION JUNE2002 CPN 85623031 33519009601 ind1 GENERATOR PARTS LISTS GENERATOR MODEL G270...
Страница 151: ...G270 EDITION JUNE2002 27...
Страница 184: ......
Страница 185: ......
Страница 186: ......
Страница 212: ...26 INSTALLATION AND MAINTENANCE LSA 46 2 47 1 ALTERNATORS SPARE PARTS Ref 2981 GB 4 33 a 04 00 LEROY SOMER...
Страница 213: ...27 INSTALLATION AND MAINTENANCE LSA 46 2 47 1 ALTERNATORS SPARE PARTS Ref 2981 GB 4 33 a 04 00 LEROY SOMER...
Страница 214: ...MOTEURS LEROY SOMER 16015 ANGOUL ME CEDEX FRANCE Imprimerie MOTEURS LEROY SOMER RC ANGOULEME B 671 820 223...