9
16 - O
Options cconnected tto tthe iinterface
17 - SSorties rrelais
!
Max switching voltage: 250Vac (277Vac for *)
!
Mains and Stand-by contactor control outputs: 4.9A, 1500VA breaking capacity at cos
ϕ
=0.7
!
Electro-flaps outputs: 500mA & CIC remote contact:1A
!
MX coil control output (*): 4.9A (optional relay on baseplate)
18 - TTransistor ooutputs
!
Protected against short-circuit
!
Output for fuel solenoid/panel lighting: 700mA
!
Other outputs: 300mA
19 - H
Hardware cconfiguration
!
C14/C15 connector, auxiliaries voltage selection
!
C7 dip-switch, RS485 terminator
!
P3 dip-switch, CAN bus terminator
!
Dip-switch selection for VDE option
20 - EEnvironment aand sstandards
!
Operating temperature: -15°C to +60°C
!
Storage temperature: -20°C to +70°C
!
Resistance to shocks: IK01, vibration: to CEI68-2-6
!
Salt mist resistance : 96 hours according to EN68011-2-11
!
Humidity : 95 % of humidity at 45°C.
!
EMC :
- Generic standards EN50081-2 and EN50082-2
- Emissions EN55011 Class A
- Immunity EN61000-4.2, EN6100-4.3, EN61000-4.4, EN61000-4.6, EN61000-4.8, ENV50201
!
CE mark, UL listed, CSA certified
*)indication and fault/shutdown for oil temperature, low oil level,
water heater failure and alarm/warning for, oil pressure, water
temperature, oil temperature, air damper control, starter 2 control.
Option description
CB
CB12
external start-up command
x
x
auto predispo external command
x
x
3ph+neutral or 1ph+N mains connection
x
x
battery charger (3 possible ratings)
x
x
water heater (3 poss. depending on supply V)
x
x
hooter
x
x
RS485 for monitoring or remote
management
x
x
option 3 module / CAN bus connection
x
x
additional engine kit (9 options) (*)
x
electro-flaps (DC or AC)
x
anti-condensation heater
x
EJP (switch, adv. warning and start-up)
x
1ph or 3ph fuel pump (control & power)
x
Air cooler (low level, disconnection)
x
differential protection and MX coil contr ol
x
CIC protection with remote contact and MX
coil control
x
bulk tank fuel pump (CF80, low level,
retention bund)
x
AMPG with optional RS485
x
option 4 module / CAN bus connection
x
three-alarm (OP,WT,OT) and module 4 kit
x
French only
Содержание G 270
Страница 2: ......
Страница 17: ...Alternator 15...
Страница 28: ......
Страница 29: ......
Страница 30: ......
Страница 31: ...User s manual Ingersoll Rand Control unit Intellisys Level 1 1 06F R f constructeur R f GPAO 33502013801...
Страница 57: ......
Страница 58: ......
Страница 121: ......
Страница 122: ...7739614 1 English 04 2002...
Страница 123: ......
Страница 124: ......
Страница 125: ...EDITION JUNE2002 CPN 85623031 33519009601 ind1 GENERATOR PARTS LISTS GENERATOR MODEL G270...
Страница 151: ...G270 EDITION JUNE2002 27...
Страница 184: ......
Страница 185: ......
Страница 186: ......
Страница 212: ...26 INSTALLATION AND MAINTENANCE LSA 46 2 47 1 ALTERNATORS SPARE PARTS Ref 2981 GB 4 33 a 04 00 LEROY SOMER...
Страница 213: ...27 INSTALLATION AND MAINTENANCE LSA 46 2 47 1 ALTERNATORS SPARE PARTS Ref 2981 GB 4 33 a 04 00 LEROY SOMER...
Страница 214: ...MOTEURS LEROY SOMER 16015 ANGOUL ME CEDEX FRANCE Imprimerie MOTEURS LEROY SOMER RC ANGOULEME B 671 820 223...