35
OPERATING INSTRUCTIONS – INTELLISYS OPTION
SSR UP6 40, SSR UP6 50PE, SSR UP6 50PEI, HF50–PE,
EP50–PE, HP50–PE, HXP50–PE
FULL VOLTAGE WIRING SCHEMATIC
DRYER OPTION
PORO OPTION
DRYER OPTION
SEE NOTES 1 & 2
LEGEND
3APT
Sensor, presure, line/sump
2ATT
Sensor, temperature, airend discharge
3ATT
Sensor, temperature dryer air (option)
COM
Port, communications / test / service / sequencer
CPT
Transformer
EDV
Valve, electric drain
ES
Switch, emergency stop
FOL
Overload, internal fan (option)
1FU, 2FU Fuses, primary voltage
3FU
Fuse, secondary voltage
4FU, 5FU Fuses, low voltage
6FU,
7FU, 8FU
Fuses, dryer fan (option)
1M
Contactor, main
1Ma
Contact, aux. main contactor
3M
Contactor, dryer compressor (option)
4M
Contactor, dryer fan (option)
MMS
Starter & overload, fan motor
MMSa
Contact, fan motor overload
MOD
Option, modulation control
1MTR
Motor, compressor
2MTR
Motor, fan
3MTR
Motor, dryer compressor (option)
4MTR
Motor, dryer fan (option)
OL
Overload, main motor
OLa
Contact, main motor overload
3OL
Overload, dryer compressor (option)
OM
Module, option
http://ai
r.ingersollrand.com