Installation / Assembly
T-Rack
®
3.0 Series
– Assembly Instructions 1.1(2019-03) E inge
Page 75 of 84
© inge GmbH
Step
Activity
1
Lubricate the gaskets with glycerin
a) Remove the gaskets of the flexible composite
couplings 6”.
b) Lubricate the gaskets with glycerin on the inside and outside.
2
Mount the gasket on the end pipe
a) Remove the protective cap from the corresponding pipe.
b) Mount one of the lubricated gaskets over the opening of the corresponding end pipe.
c) Push the gasket onto the corresponding pipe so it is flush with the end of the pipe.
3
Attach the compensating pipe
a) Position the compensating pipe on the corresponding pipe end.
b)
Place a flexible coupling 6” half-shell around the gasket.
Ensure that the contact surfaces of the coupling half-shells are resting in the provided grooves.
c)
Place the second flexible coupling 6” half-shell on the first and insert the two bolts in the
openings.
d) Tighten the flexib
le coupling 6” with two nuts M12 and washers using an open-end or box
wrench (size 19) until the contact surfaces of both coupling halves are flush and resting against
each other without a gap.
Ensure that the nuts are tightened evenly and alternately.
Ensure that the square screw neck of each screw is correctly positioned in each
threaded hole.