Installation / Assembly
T-Rack
®
3.0 Series
– Assembly Instructions 1.1(2019-03) E inge
Page 58 of 84
© inge GmbH
5.12
Mounting the Filtrate Header
5.12.1 Mounting the first Filtrate Header
Step
Activity
Figure
1
Lubricate the gaskets with glycerin
a)
Remove the gaskets of the flexible couplings 2”.
b)
Lubricate the gaskets with glycerin on the inside and
outside.
2
Prepare the filtrate header
a)
Mount a lubricated gasket on the filtrate port.
b)
Push the gasket onto the filtrate port so it is flush with the
end.
c)
Repeat procedures a) to c) for all further filtrate ports.
3
Position the filtrate header
Position the filtrate header on the mounting clamp PE of
modules 1 and 11.
The end of the pipe with the smallest distance to the first
connection must come to rest above module 1.