![Infranor XtrapulsEasy 60VDC Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/infranor/xtrapulseasy-60vdc/xtrapulseasy-60vdc_installation-manual_2058371013.webp)
13
XtrapulsEasy
™-DB - Installation Guide
Chapter 3
– Inputs-Outputs
3.1.2 - CANopen® communication bus
RUN
: The CANopen® RUN LED indicates the status of the NMT state machine (see DS-301
– 9.52 NMT state
machine):
CAN RUN LED
STATUS
FLASHING
STOP
BLINKING
PRE-OPERATIONAL
ON
OPERATIONAL
See "DR-303-3 Indicator specification" for more information.
Note:
Each drive of the network must be configured with one single address.
The factory-set addressing is address 1 and the default communication speed is 1Mbit.
3.2 - X10 CONNECTOR: FEEDBACK / CAN / TTL HALL / I/O
The feedback and I/O connector is a 2.54mm pitch 2x15 pins header.
Recommended mating references are listed below:
Manufacturer
REFERENCE
FCI
87606-315LF
HARWIN
M20-7831546
SAMTEC
SSQ-115-01-G-D
E-TEC
BL2-030-S842-55
The pinout of this connector is described below.
3.2.1 Resolver feedback
PIN
FUNCTION
I/O
DESCRIPTION
1
RS232 TX
O
Transmit data RS-232
3
RS232 RX
I
Receive data RS-232
2
CAN H
IO
Line CAN-H (dominant high)
4
CAN L
IO
Line CAN-L (dominant low)
12
+24V
I
24V
DC
supply: +/- 15%
Consumption: 100mA without digital output loads
6
GND
14
GND
17
GND
30
GND
8
OUT1
O
"high side" logic outputs 24V / 500mA
10
OUT2
O
19
IN1
I
All logic inputs are referenced to GND
Vin voltage = 18V < Vin < 27V
Input impedance Zin = 10k
Ω
21
IN2
I
23
IN3
I
25
IN4
I
15
+5V
O
Encoder supply voltage (max. current = 300mA)
26
R1 (ref)
O
Resolver signal
24
R2 (reference -)
O
Resolver signal
16
S3 ()
I
Resolver signal
18
S1 (cosine -)
I
Resolver signal
1000ms
200ms
ON
OFF
200ms
200ms
ON
OFF