background image

16

17

16. MOUNTING THE INFRARED 

ILLUMINATOR

The TD50L includes an optional Infrared Illuminator that can be used 

to supplement available light when conditions require. To use the 

Illuminator, you must first install it onto the included QD mount:

1.  Install the body of the Illuminator into the smaller-diameter end 

of the mount and use the included Allen wrench to tighten the 

two screws until snug.

2.  Open the larger-diameter end of the Illuminator mount by 

loosening the tension arm on the top of the mount.

3.  Place the open end of the mount around the body of the TD50L, 

ensuring that the placement will not impair the operation of the 

scope or weapon, and tighten the tension arm to secure it. 

4.  Twist the tension arm to adjust tension, as needed.

To turn the Illuminator on and adjust the beam angle: 

1.  Turn the tail switch to cycle between the three available power 

levels (low, medium, and high output). 

2.  Once a suitable power lever is selected, adjust the beam path by 

turning the bezel of the Illuminator (flood to beam). 

3.  Using the included Allen wrench, slightly loosen the two screws 

on the small side of the mount holding the Illuminator in place. 

4.  Adjust the Illuminator by pointing it so that the beam lands in 

the desired position in your sight picture, and retighten the two 

screws. 

CAUTION: 

 Never look directly into the beam of the Illuminator to 

check operation. The Illuminator uses concentrated infrared light, 

which while not visible to the human eye, can cause permanent 

physical damage.

17.  OPERATING INSTRUCTIONS

Control Features

The BOLT TD50L is operated via four control buttons and a large 

metal tactile control turret. The large, easy-find control turret provides 

audible and tactile feedback when twisted and when pressed. 

The control buttons can be used to perform shortcut operations from 

the home screen, as well as in the menu and full-screen interfaces. 

See 

Description of Control Buttons and Shortcuts

 on page 6 for 

shortcut button details. 

Powering On / Starting

1.  Open the objective lens cap 

(15)

.

2.  Long press the 

Power

 

 

Button

 for 2 seconds to power on the 

BOLT TD50L. The home screen appears after 3 seconds.

To determine the current charge of the built-in battery pack, check 

the battery icon on the right side of the status bar at the top of the 

viewscreen. See 

Battery Status Indicators

 on page 12.

WARNING:  

Don’t point the objective lens towards any intense 

energy sources, such as laser radiation or the sun. This may render 

the electronic components inoperative. The warranty does not 

cover damage caused by improper operation.

Powering Off / Stopping 

To power off the BOLT 

TD50L:  

1.  Press and hold the 

Power

 

 

Button

The standby screen 

will open, showing a 

3-second countdown. 

2.  Continue holding 

the 

Power

 

 

Button

 until the 

3-second countdown 

completes. 

NOTE:  Releasing the 

Power

 

 

Button

 at any time before the 

countdown reaches zero will stop the shutdown process.

WARNING:  

Do not remove the power supply when saving data, 

otherwise the data may not be saved.

00:03

Содержание BOLT DIGITAL Series

Страница 1: ...I N F I R A Y O U T D O O R BOLT DIGITAL SERIES Bolt Action Optimized Digital Night Vision Scope User s Manual Outdoor...

Страница 2: ...the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the d...

Страница 3: ...i Fi module for external connectivity to App Picture in Picture PIP Extended eye relief User friendly interface 3 TECH SPECS BOLT TD50L SERIES TD50L SENSOR Resolution 1440 1080 Pixel Size 4 m Frame Ra...

Страница 4: ...AC18 BOLT Standard Scope Mount Rings IRAY AC37 BOLT 18650 Battery Extender IRAY AC70 BOLT Digital Series Infrared Illuminator IRAY AC71 Standard Rubber Eyeguard for BOLT IRAY AC74 Objective Lens Cap...

Страница 5: ...ort Press Long Press Home screen Adjust the screen brightness Enter exit the stadiametric rangefinder Photo Button Current Screen Menu Short Press Long Press Home screen Take a photo Start stop record...

Страница 6: ...s and hold the Brightness and Palette Buttons at the same time for 15 seconds to activate the reticle 2 Short press the Control Turret to enter the quick menu see Using the Quick Menu on page 21 a Sel...

Страница 7: ...battery b See Battery Status Icons on page 12 for additional battery information WARNING Never charge the battery pack with a USB adapter that is greater than 5V 2A NOTES You may charge and operate B...

Страница 8: ...included are compatible with the BOLT TD50L Using with the Optional Auxiliary Battery When both the built in battery pack and the auxiliary battery are fully charged the BOLT TD50L will select the aux...

Страница 9: ...y turning it counterclockwise 2 Connect the smaller USB C end of the data cable to the USB C port 9 3 Connect the standard USB end of the data cable to the external power supply The BOLT TD50L will au...

Страница 10: ...ses concentrated infrared light which while not visible to the human eye can cause permanent physical damage 17 OPERATING INSTRUCTIONS Control Features The BOLT TD50L is operated via four control butt...

Страница 11: ...icle appear sharp and in focus No additional diopter adjustments are required unless the user wishes to make changes NOTES After this initial adjustment there is no need to rotate the eyepiece adjustm...

Страница 12: ...on the operating status of the BOLT TD50L Series 1 2 3 4 5 6 7 8 9 1 Imaging Mode Shows the set imaging mode day moon star Day is the default 2 Zeroing Profile Distance Shows the selected zero profile...

Страница 13: ...he desired zero distance 2 Confirm that the rifle is empty safe and pointed in a safe direction with no ammunition near the weapon 3 Adjust the image and device settings following the steps in the Qui...

Страница 14: ...Recorded photos are saved to the internal memory card in jpg format videos are saved in mp4 format a Photos are saved in IMG_HHMMSS_XXX jpg format b Videos are saved in VID_HHMMSS_XXX mp4 format c HH...

Страница 15: ...3 Enter the Wi Fi password The default password is 12345678 4 Press the Join button When Wi Fi is successfully connected the user may manipulate the BOLT TD50L via the InfiRay Outdoor App See Using th...

Страница 16: ...app are saved to the mobile device instead of the internal storage of the BOLT TD50L Once connected you can access files saved to the mobile device In the App press the ViewFinder icon at the bottom...

Страница 17: ...xpand the space between the lines b Rotate counterclockwise to shrink the space between the lines 2 As you adjust the space between the horizontal lines the rangefinder values on the right side of the...

Страница 18: ...C with distance selected See the Zero Distance Submenu and Reticle Zeroing on the next page for instructions on customizing the nine zero distances 1 Long press the Control Turret to enter the main m...

Страница 19: ...sition 5 White Dot Indicates center of initial reticle position NOTE The red X indicates the point of impact It is shown in the figure for illustration purposes and is not an interface element To zero...

Страница 20: ...e two triangle icons will indicate the selected digit 5 Long press the Control Turret to save the custom zero distance and return to the Zero Distance submenu 6 The new zero distance appears in the st...

Страница 21: ...ss the Control Turret to switch between digits The two triangle icons indicate the selected digit 5 Long press the Control Turret to save the date and return to the home screen SETTINGS MENU TIME Set...

Страница 22: ...ol Turret to select the status auto hiding menu item 2 Short press the Control Turret to enter the auto hiding submenu 3 Rotate the Control Turret to move through the options on and off Auto hiding is...

Страница 23: ...ing your published warranty period iRayUSA will repair or replace at its discretion any optic that becomes defective during normal use Additionally if we cannot fix your optic in less than one week we...

Страница 24: ...microfiber lens cloth There is condensation on the interior or exterior optical surfaces of the lens Wipe the outside optical surfaces with the included microfiber lens cloth Allow the BOLT TD50L to...

Страница 25: ...ubject to change without notice For the most up to date specs go to irayusa com Not responsible for typographical errors Ver 1 1080122 800 Railhead Road 316 Fort Worth TX 76106 800 769 7125 682 499 00...

Отзывы: