20
LT 6117 (12/13 Iss 11)
480 FL
Installation Instructions
SECTION TEN
Checking Operation of Fire
REFIT GLASS PANEL AND FIREPLACE FRAME
COVERS
Locate the glass panel within the bottom glass retaining slot and
push back against the firebox seals.
Locate the glass fixing bracket over the top edge of the glass
panel and slide over the two M4 studs.
Using the two M4 nuts provided tighten the glass fixing bracket.
Insert the air grill within the bottom space of the fireplace frame.
Finally insert the LH and RH side covers between the sides of the
glass panel and fireplace frame.
CHECKING
FOR
COMBUSTION
PRODUCTS
CLEARENCE
IMPORTANT
:-The smoke test must be carried out with the fire
starting from cold.
Light the fire and leave at maximum input.
Close all the doors and windows.
After five minutes fit the smoke match in a holder and position
as illustrated with the head of the match just inside the test
opening.
Run the match along the top edge
All smoke
must be drawn
into the test opening if the clearance is satisfactory.
If spillage occurs wait a further five minutes and repeat the test.
Repeat the test with doors open and with any extractor fans in
other rooms in operation.
If spillage is detected the cause must be discovered and the
fault corrected, if the fault cannot be corrected, disconnect the fire from the gas supply and seek
expert advice. Spillage can be caused by a restriction in the flue system, down draught or
insufficient ventilation into the room where the fire is installed.
ADVISE CUSTOMER THAT:
The glass front of this fire acts as a dress guard, conforming to BS 1945 (1997) and satisfies the
heating appliance regulations (1991) however; a fireguard conforming to BS6539 (1997) must be
used to protect young children, the elderly, or infirm.
The curing effect of heating the logs and other refractory components will cause an initial odour.
This is due to the starch used in the manufacturing process and is non-toxic.
Any debris should be cleaned from the appliance. A vacuum cleaner can be used but only after all
the loose logs have been removed.
The appliance should be serviced annually by a competent person in accordance with these
instructions and the appliance checked for spillage in accordance with the method detailed in
these instructions.
Demonstrate changing the batteries.
Demonstrate the lighting and extinguishing procedures to the user and the removal and refitting of
the glass panel for cleaning. Refer to the user section of this booklet.
If ventilation is fitted for any reason it must be checked regularly to ensure freedom from
obstructions.
Hand these instructions over to the user along with the spare batteries and glass removal
tool.