background image

15 

LT 6117 (12/13 Iss 11)

 

 

 

 
480 FL 

Installation Instructions

 

 

 

SECTION SEVEN 

Regulations and Warnings 

 

 

  This appliance must only be installed in Great Britain or Ireland. 

  The appliance is suitable for use on natural gas only. 

 

GB (Great Britain)

 This fire does not normally require purpose build ventilation. 

 

IE (Ireland)

 Permanent ventilation must comply with the current edition of IS813. 

 

In GB

(Great Britain)

 

It  is  the  law  that  all  gas  appliances  must  be  installed  by  a  competent  person;  i.e.  a  GAS  SAFE 
registered installer, in accordance with the Current Gas Safety (Installation And Use) Regulations 
(as  amended),  all  relevant  parts  of  the  local  and  national  building  regulations  and  all  relevant 
recommendations of the following British Standards. Failure to do so could lead to prosecution. 

The following are relevant codes of practice and British Standards: - 
B.S. 5871  

 

 

 

 

 

 

B.S. 5440 PART 1 & PART 2 

 

 

 

B.S. 6891  
This appliance must  be  installed  to  current  versions  of the  above  standards  and  include any 
relevant amendments to:- 
The Building Regulations Issued By The Department Of The Environment.

 

The  Building  Standards  (Scotland)  (Consolidated)  Regulations  Issued  By  The  Scottish 
Development Office.  

 

IN IE, (Ireland)

 

The  appliance  must  be  installed  by  a  competent  person  and  installed  in  accordance  with  the 
current  edition  of  I.S.813  Domestic  Gas  Installation,  the  current  building  regulations,  and  the 
current ETCI rules for electrical installation, if appropriate.   

 

Prior  to  the  installation  ensure  that  the  local  distribution  conditions  (identification  of  type  of  gas 
and pressure) and adjustment of the appliance are compatible. (G20@20mbar & G21@37mbar) 

 

 

WARNINGS 

  The glass front of the fire act as a dress guard,  conforming to BS 1945 (1971) and satisfies the 

heating  appliance  regulations  (1991)  However,  a  guard  conforming  to  BS6539  (1984)  must  be 
used to protect young children, the elderly or infirm. 

 

This appliance incorporates a safety device in the form of an Oxygen depletion system. IT 
MUST  NOT  BE  ADJUSTED  OR  PUT  OUT  OF  OPERATION!  THIS  IS  A  NON-SERVICABLE 
ITEM  AND  MUST  BE  EXCHANGED  AS  A  COMPLETE  ASSEMBLY;  USING  ONLY  THE 
ORIGINAL MANUFACTURER'S PART.

 

  A suitable proprietary fire surround with a 150°C minimum rating is required. 

  During  initial  firing,  an  odour  may  be  evident.  This  is  the  starch  binder  used  during  the 

manufacture of the fibre components of the fire, and there are 

no

 

harmful

 effects produced. 

 

Care  must  be  taken  to  prevent  any  damage  being  caused  to  surrounding  soft  furnishing  or  decoration;  e.g.  many 
embossed vinyl wall coverings may become discoloured if placed too close to the appliance. 

 

Содержание 480 FL

Страница 1: ...NSTRUCTIONS Please read these instructions carefully before you start installing or using this appliance Keep this booklet handy for future reference This appliance is for use in Great Britain or IREL...

Страница 2: ...l Bed Layout 10 SECTION FIVE General Points 12 INSTALLATION INSTRUCTIONS SECTION SIX Appliance Data 13 SECTION SEVEN Regulations and Warnings 14 SECTION EIGHT Siting the Appliance Flue Class1 15 SECTI...

Страница 3: ...cleaning the coals or cleaning after servicing installation it is recommended that it be of the type fitted with a HEPA filter Disposal of refractory ceramic materials To keep dust to a minimum these...

Страница 4: ...otland or The Building Regulations Northern Ireland and The Current I E E Wiring Regulations if appropriate In IE Ireland the appliance must be installed by a competent person and installed in accorda...

Страница 5: ...from manual to Room Thermostat setting and vice versa When Room Thermostat mode is active the display shows the set temperature value and the AUTO icon will appear on the LCD display By using the arr...

Страница 6: ...y for three seconds the written clock will appear To change the clock settings repeat the above described operation Change From Celsius to Fahrenheit With remote OFF keeping pressed key at least for 5...

Страница 7: ...REPLACE APPLIANCE BATTERIES 6 High Power Alkaline C 1 5V a Remove the fireplace frame covers which are held in place with magnets b Lift out the air grill cover from the bottom of the frame assembly c...

Страница 8: ...blow the debris into the hole as this may cause more of a restriction and not rectify the problem Note Take care when cleaning in this area so as not to damage the pilot assembly GLASS CLEANING From...

Страница 9: ...th great care The moulded shapes may be removed for cleaning They can be brushed very gently with a soft brush to remove dust or any deposits A vacuum cleaner may only be used after the loose componen...

Страница 10: ...yout Please make sure no loose shapes are placed directly on top of the pilot shield Place the 2 log shapes along the front edge of the burner top plate Place a single layer of small bark chippings al...

Страница 11: ...ers Instructions SECTION FOUR Fuel Bed Cleaning and Layout Place the 2 log shapes along the rear of the air tray assembly Position a single layer of bark chippings along the front edge of the air tray...

Страница 12: ...12 LT 6117 12 13 Iss 11 480 FL Users Instructions SECTION FOUR Fuel Bed Cleaning and Layout Continued Place the two log shapes as shown Place the two log shapes as shown...

Страница 13: ...then pull clear and remove from location studs Carefully lift the glass panel from within the bottom retaining slot Remove the log fuel bed shapes Lift out the air tray assembly from the location poi...

Страница 14: ...iance 6 x 1 5V C high power alkaline Appliance Dimension NOTE The efficiency of this appliance has been measured as specified in BS7977 1 2009 A1 2013 and the result is 73 67 The gross calorific value...

Страница 15: ...he appliance must be installed by a competent person and installed in accordance with the current edition of I S 813 Domestic Gas Installation the current building regulations and the current ETCI rul...

Страница 16: ...5 mm 5 ins minimum diameter flue liner conforming to BS 715 may be used Provided a suitable sealing plate is fitted to the base of the liner and the appliance does not restrict the opening into the li...

Страница 17: ...le fixing at a height that clears the out fire box assembly Remove the inner box and top inspection cover as described in section five general points With the out fire box in place attach the gather h...

Страница 18: ...liance GAS SUPPLY ROUTING Use rigid or semi rigid tube to connect the supply Determine the gas supply pipe route to the appliance before installing the fire Fixing Firebox Assembly Slide the firebox i...

Страница 19: ...n 502mm from the centre of the firebox The horizontal stud work should not be less than 764mm from the base of the firebox This will ensure 50mm minimum clearance from the sides and 110mm clearance fr...

Страница 20: ...the fault corrected if the fault cannot be corrected disconnect the fire from the gas supply and seek expert advice Spillage can be caused by a restriction in the flue system down draught or insuffici...

Страница 21: ...R TRAY Remove RH and LH side covers undo glass fixing Remove glass panel Remove the loose fuel bed components Disconnect battery leads and remove appliance battery pack Remove gas supply cover Disconn...

Страница 22: ...n the supply pipe at the pilot Carefully pull off the ignition lead Disconnect the thermocouple at the end of the main control valve Remove the cross headed nut holding the pilot to the chassis Carefu...

Страница 23: ...23 LT 6117 12 13 Iss 11...

Страница 24: ...date and supported by receipts in each case 5 This warranty is not transferable and relates to the original installation only 6 The Registration Form must be correctly filled out and returned 7 The a...

Страница 25: ...25 LT 6117 12 13 Iss 11...

Страница 26: ...Date of First annual service Engineer Name Gas Safe Registration No Date of Second annual service Engineer Name Gas Safe Registration No Date of Third annual service Engineer Name Gas Safe Registratio...

Страница 27: ...27 LT 6117 12 13 Iss 11...

Страница 28: ...YOUR DETAILS Name ________________________________ Address ________________________________ Post Code TELEPHONE No PRODUCT DETAILS Model 480 FL Serial No Date of Purchase This information can be found...

Страница 29: ...29 LT 6117 12 13 Iss 11...

Страница 30: ...30 LT 6117 12 13 Iss 11...

Страница 31: ...31 LT 6117 12 13 Iss 11...

Страница 32: ...ing Label 1409 ID Label Packing Labels Side Covers 6016 Restrictor Plate Inlet Cover 6006 Serial Number Inspector Infinity 480 FL Product ID Label A 0342 Serial No Prefix MY Lpg Burner Tray Box Assemb...

Отзывы: