background image

13 

LT 6117 (12/13 Iss 11)

 

 

 

480 FL 

Users Instructions

 

 

SECTION FIVE 

General Points 

 

Like all appliances incorporating an aerated burner a low frequency 
noise  may  be  heard,  particularly  on  the  low  setting,  this  is  quite 
normal and does not affect the operation of the appliance. 
 
It  is  advised  that  a  competent  person  service  the  480  FL  fire 
annually. The fire is more likely to provide trouble-free operation. 
 
Dulling and slight discoloration inside the firebox will occur adding to 
the realism of the appliance. This is normal. 
 
It is important that: - 
The  chimney  or  flue  is  checked  annually  to  ensure  clearance  of 
combustion products.  This can be inspected by removing the inner 
firebox  and  removal  of  the  inspection  covers  located  on  the  back 
and  top  of  the  outer  firebox.  This  can  be  obtained  by  doing  the 
following.  
 

  Remove the two side covers LH and RH  which are held with 

magnets.  

  Undo the two M4 nuts retaining the glass fixing bracket using 

the  tool  provided  then  pull  clear  and  remove  from  location 
studs. 

  Carefully lift the glass panel from within the bottom retaining 

slot. 

  Remove the log fuel bed shapes. 

  Lift  out  the  air  tray  assembly  from  the  location  points  within 

the shelf. 

  Pull  out  the  air  grill  and  disconnect  the  battery  holder  from 

the lead and remove. 

  Remove  the  two  screw  retaining  the  gas  connection  cover 

from  within  the  burner  shelf  and  remove  cover.    Shut  down 
restrictor elbow and disconnect the 8mm inlet nut. 

   Undo the three fixing screws from the burner tray and lift out 

burner tray assembly taking care not to damage the liners. 

  Remove  the  six  M4  nuts  from  the  front  face  of  the  inner 

firebox. 

  Taking  care  not  to  damage  the  top  liner  remove  the  three 

fixing screw from the top of the inner firebox. 

  Carefully  pull  the  inner  firebox  forward  to  clear  the  outer 

firebox assembly. 

  Remove the inspection plates located within the outer firebox 

taking care not to damage the sealing gaskets. 

  After  inspection  for  clearance  is  completed  reassemble  in 

reverse order. 

The only user removable parts are: - 

 

Refractory Fire bed Components 

 

Side covers and air grill. 

 

Glass panel top fixing bracket. 

 

Glass panel. 

Содержание 480 FL

Страница 1: ...NSTRUCTIONS Please read these instructions carefully before you start installing or using this appliance Keep this booklet handy for future reference This appliance is for use in Great Britain or IREL...

Страница 2: ...l Bed Layout 10 SECTION FIVE General Points 12 INSTALLATION INSTRUCTIONS SECTION SIX Appliance Data 13 SECTION SEVEN Regulations and Warnings 14 SECTION EIGHT Siting the Appliance Flue Class1 15 SECTI...

Страница 3: ...cleaning the coals or cleaning after servicing installation it is recommended that it be of the type fitted with a HEPA filter Disposal of refractory ceramic materials To keep dust to a minimum these...

Страница 4: ...otland or The Building Regulations Northern Ireland and The Current I E E Wiring Regulations if appropriate In IE Ireland the appliance must be installed by a competent person and installed in accorda...

Страница 5: ...from manual to Room Thermostat setting and vice versa When Room Thermostat mode is active the display shows the set temperature value and the AUTO icon will appear on the LCD display By using the arr...

Страница 6: ...y for three seconds the written clock will appear To change the clock settings repeat the above described operation Change From Celsius to Fahrenheit With remote OFF keeping pressed key at least for 5...

Страница 7: ...REPLACE APPLIANCE BATTERIES 6 High Power Alkaline C 1 5V a Remove the fireplace frame covers which are held in place with magnets b Lift out the air grill cover from the bottom of the frame assembly c...

Страница 8: ...blow the debris into the hole as this may cause more of a restriction and not rectify the problem Note Take care when cleaning in this area so as not to damage the pilot assembly GLASS CLEANING From...

Страница 9: ...th great care The moulded shapes may be removed for cleaning They can be brushed very gently with a soft brush to remove dust or any deposits A vacuum cleaner may only be used after the loose componen...

Страница 10: ...yout Please make sure no loose shapes are placed directly on top of the pilot shield Place the 2 log shapes along the front edge of the burner top plate Place a single layer of small bark chippings al...

Страница 11: ...ers Instructions SECTION FOUR Fuel Bed Cleaning and Layout Place the 2 log shapes along the rear of the air tray assembly Position a single layer of bark chippings along the front edge of the air tray...

Страница 12: ...12 LT 6117 12 13 Iss 11 480 FL Users Instructions SECTION FOUR Fuel Bed Cleaning and Layout Continued Place the two log shapes as shown Place the two log shapes as shown...

Страница 13: ...then pull clear and remove from location studs Carefully lift the glass panel from within the bottom retaining slot Remove the log fuel bed shapes Lift out the air tray assembly from the location poi...

Страница 14: ...iance 6 x 1 5V C high power alkaline Appliance Dimension NOTE The efficiency of this appliance has been measured as specified in BS7977 1 2009 A1 2013 and the result is 73 67 The gross calorific value...

Страница 15: ...he appliance must be installed by a competent person and installed in accordance with the current edition of I S 813 Domestic Gas Installation the current building regulations and the current ETCI rul...

Страница 16: ...5 mm 5 ins minimum diameter flue liner conforming to BS 715 may be used Provided a suitable sealing plate is fitted to the base of the liner and the appliance does not restrict the opening into the li...

Страница 17: ...le fixing at a height that clears the out fire box assembly Remove the inner box and top inspection cover as described in section five general points With the out fire box in place attach the gather h...

Страница 18: ...liance GAS SUPPLY ROUTING Use rigid or semi rigid tube to connect the supply Determine the gas supply pipe route to the appliance before installing the fire Fixing Firebox Assembly Slide the firebox i...

Страница 19: ...n 502mm from the centre of the firebox The horizontal stud work should not be less than 764mm from the base of the firebox This will ensure 50mm minimum clearance from the sides and 110mm clearance fr...

Страница 20: ...the fault corrected if the fault cannot be corrected disconnect the fire from the gas supply and seek expert advice Spillage can be caused by a restriction in the flue system down draught or insuffici...

Страница 21: ...R TRAY Remove RH and LH side covers undo glass fixing Remove glass panel Remove the loose fuel bed components Disconnect battery leads and remove appliance battery pack Remove gas supply cover Disconn...

Страница 22: ...n the supply pipe at the pilot Carefully pull off the ignition lead Disconnect the thermocouple at the end of the main control valve Remove the cross headed nut holding the pilot to the chassis Carefu...

Страница 23: ...23 LT 6117 12 13 Iss 11...

Страница 24: ...date and supported by receipts in each case 5 This warranty is not transferable and relates to the original installation only 6 The Registration Form must be correctly filled out and returned 7 The a...

Страница 25: ...25 LT 6117 12 13 Iss 11...

Страница 26: ...Date of First annual service Engineer Name Gas Safe Registration No Date of Second annual service Engineer Name Gas Safe Registration No Date of Third annual service Engineer Name Gas Safe Registratio...

Страница 27: ...27 LT 6117 12 13 Iss 11...

Страница 28: ...YOUR DETAILS Name ________________________________ Address ________________________________ Post Code TELEPHONE No PRODUCT DETAILS Model 480 FL Serial No Date of Purchase This information can be found...

Страница 29: ...29 LT 6117 12 13 Iss 11...

Страница 30: ...30 LT 6117 12 13 Iss 11...

Страница 31: ...31 LT 6117 12 13 Iss 11...

Страница 32: ...ing Label 1409 ID Label Packing Labels Side Covers 6016 Restrictor Plate Inlet Cover 6006 Serial Number Inspector Infinity 480 FL Product ID Label A 0342 Serial No Prefix MY Lpg Burner Tray Box Assemb...

Отзывы: