background image

GB

GB

 1

Assembly and Operation Instructions

ebios-fire inserts

Summary of Contents for ebios-fire

Page 1: ...GB GB 1 Assembly and Operation Instructions ebios fire inserts ...

Page 2: ... to others Together with our partners at specialist dealerships we offer first class prod ucts that stir the emotions evoking feelings of security and comfort However to ensure that we achieve this we recommend that you read the operating manual carefully to quickly familiarise yourself with your decorative fire in all its details In addition to information on how to use it this manual also contai...

Page 3: ...l 15 3 3 Initial operation 16 3 3 1 Initial operation of the ebios insert 17 3 4 Topping up with fuel 18 3 5 Safe shutdown 19 4 Cleaning and care 19 4 1 Cleaning of trim component 19 5 Maintenance Troubleshooting 20 5 1 Unit and glass seriously soots up fast and unevenly 20 5 2 Fire ist difficult to ignite 20 5 3 Bad smell 20 5 4 Appearance of flames changes 20 5 5 Spilt ethanol catches fire 20 6 ...

Page 4: ...ening and NOT via the burner channel We recommend that you put out the ebios fire by run ning it until the fuel tank runs dry When not in operation the extinguishing slide must be above the burner Only allow the device to be refilled by individuals who are familiar with the safety instructions and who you have trained on its operation The ebios fire is not a heater it is a decorative fire Bio etha...

Page 5: ...f explosive ignition of the fuel Correct installation and proper handling are essential to ensure safe reliable operation of your fire The unit is not self supporting It must be installed as per the instructions ensuring it is horizontal Never move the burner when the unit is operating The unit must be installed in such a way that it cannot be knocked over or tilted The fire should be installed an...

Page 6: ...y diminish until the flame is no longer clearly visible Point this out to your children and other per sons in the household This information refers only to the ebios fire air demand for combus tion Any further air consuming devices in the room must be considered separately Overview of model illustrations Model ebios Front 1V Placement Installation in furniture panel Installation in fireplace casin...

Page 7: ...lation in fireplace casing Number of burners 1 Width mm 853 Depth mm 450 Height mm 665 Weight kg 88 5 kg Model ebios left end open 2R Placement Installation in furniture panel Installation in fireplace casing Number of burners 1 Width mm 853 Depth mm 450 Height mm 665 Weight kg 88 5 kg ...

Page 8: ...on in fireplace casing Number of burners 1 Width mm 848 Depth mm 450 Height mm 665 Weight kg 88 5 kg Model ebios double sided FD Placement Installation in furniture panel Installation in fireplace casing Number of burners 1 Width mm 862 Depth mm 442 Height mm 661 Weight kg 88 5 kg ...

Page 9: ...nd Health Vbf Fire Safety Ordinance of the relevant federal state BsV State fire prevention codes LBO Regional building regulations GefStoffV Ordinance on hazardous materials The ebios fire may only be installed in rooms and locations where the posi tion structural conditions and type of use are without risk The floor area of the installation room must be large enough and designed such that the eb...

Page 10: ...rs In garages In areas where highly flammable or explosive substances or com pounds are processed stored or manufactured in quantities constituting an ignition or explosion hazard In badly ventilated areas In unsupervised publicly accessible areas In areas that are not protected against crossventilation On tables furniture shelves etc 2 5 INSTALLATION ASSEMBLY The ebios insert is a ready to use un...

Page 11: ... hazard All objects such as door fronts must be kept clear of the hot air flow above the ebios air outlet The surfaces of the front cover in particular above the insert must be heat resistant to 65 C 2 6 1 MINIMUM FURNITURE FIREPLACE CASING DESIGN DIMENSIONS The front plate of the furniture unit should be of 2 part construction to facilitate installation The front plate cut out size is 755x528 mm ...

Page 12: ...ing holes are provided at each side for this purpose Fig 6 Use suitable screws 4 Fit the front panels in place 5 Slot the Quadra Inside into the ready prepared cut out in the fire cham ber of the fire insert 6 Here s how to open the housing cover Fig 4 Minimum dimensions distances for custom made furniture A ebios insert B Furniture Fig 5 Example of custom made fireplace fireplace casing Top view ...

Page 13: ...si tioning so that there is a uniform air gap all round between the housing cover and the flame area refer to Fig 7 to ensure an adequate air supply Otherwise the housing cover may soot up and the flames may not burn evenly 10 Next place the 2 panes of protective glass in position 2 7 FIRE PRECAUTIONS MINIMUM DISTANCES WITH EBIOS INSERT Fig 7 Air gap approx 9 mm without cover panel Fig 8 ...

Page 14: ...re hazard Burning releases thermal energy which heats up the burner the enclo sure surfaces the glass panes depending on model and the protective glass Never touch any elements without appropriate protection e g heat protection gloves Risk of burning Never leave the fire unattended whilst it is burning With the Quadra Inside model the enclosure covers must be closed and the protective glass in pla...

Page 15: ...er opening never via the burner channel see fig 1 Should you accidentally spill ethanol please remove this immediately and before igniting the burner Please be aware that the brightness of the flame may diminish until the flame is no longer clearly visible Point this out to children and other persons in the household Check that the burner is extinguished and has cooled down completely wait for at ...

Page 16: ...ort Ensure especially before initial operation that there is no ethanol in the safety pan A ebios insert B Quadra Inside A Housing B Burner mat C Burner channel D Cover plate E Stick lighter F Tank G Fill level gauge H Filler opening I Cold hand J Funnel K Key for tank cap L Bottle for soaking the burner Fig 15 ebios insert Fig 16 ebios fire Quadra Inside ...

Page 17: ...the key 7 Place the funnel into the filler open ing and add maximum 2 6 litres of Bio ethanol 8 The fill level gauge indicates the maxi mum permissible filling level The maxi mum filling level is reached when the Bio ethanol flows through the slots see arrow into the reflector curve 9 Take the bottle for wetting the burner Insert the bottle neck into the tank opening until submerged under the fuel...

Page 18: ...t 1 hour between extinguishing and refilling the burner Please also leave the possibly still hot protective glass on the unit during this time Risk of burning The burners are designed to burn until the fuel runs out Fill in less fuel if you wish to enjoy the play of the flames for a short period only To shut down the unit prematurely use the handling rod to close the burner with the cover plate To...

Page 19: ...bed under Section 3 3 1 3 5 SAFE SHUTDOWN To shut down the unit prematurely use the handling rod to close the burner with the cover plate To do this pick up the cover plate with the handling rod and place it over the burner channel 4 CLEANING AND CARE The ebios fire Quadra Inside may only be cleaned when it is cold 4 1 CLEANING OF TRIM COMPONENT Do not start cleaning before the unit has cooled dow...

Page 20: ... did not occur from the very start please check the following points Is there fuel in the burner Have you wetted the ignition mats Has the correct fuel been used 5 3 BAD SMELL Fuel in the burner whilst not in use Cover plate in place Any fuel spilled whilst filling 5 4 APPEARANCE OF FLAMES CHANGES IIs the burner mat damaged Are you using the correct fuel Are all safety distances adhered to Is the ...

Page 21: ...mbH offers a 6 months warranty on wear ing parts in the area of the fire such as wicks burner mats gaskets and ceramics 6 4 REQUIREMENT OF EFFECTIVENESS FOR THE WARRANTY The warranty period starts on the date of delivery to the dealer intermediary This must be verified from a document such as an invoice with the dealer intermediary s confirmation of delivery The warranty certificate relating to th...

Page 22: ...e case of performance in accordance with the terms of the warranty whether remediation of defects or replacement of a unit the warranty period shall be extended in respect of the replacement unit components 6 8 SPARE PARTS No spare parts other than those produced or recommended by the manu facturer shall be used 6 9 LIABILITY Damage and compensation claims not based on a defective unit supplied by...

Page 23: ...properly including correct instal lation of the burner The builder must confirm that all points specified in these instructions were observed and implemented in his design Moreover the builder must submit these instructions to the purchaser This builder confirmation to the purchaser must be made in writing ATTENTION Keep in a safe place Please keep these Instructions and a valid and clearly dated ...

Page 24: ...t merk van wereldformaat voor uw woonkamer Światowa marka do Państwa salonu Торговая марка 1 для Вашего дома D Ihr Fachhändler UK Your specialist dealer F Votre revendeur spécialisé IT Il vostro rivenditore specializzato E Sus comercios especializados NL Uw vakhandelaar PL Państwa sprzedawca РУС Ваш дилер Spartherm Feuerungstechnik GmbH Maschweg 38 D 49324 Melle Phone 49 0 5422 94 41 0 Fax 49 0 54...

Reviews: