Firmware User Manual (AE-step)
106
Revision 1.02
2019-04-24
TLE984x Firmware User Manual
ERR_LOG_CODE_NVM_PAGE_NOT_MAPPED
-34
D
NVM page is not mapped
x
ERR_LOG_CODE_NVM_INIT_MAPRAM_SECTOR
-35
D
Mapped page has double mapping
or ECC2 error when trying to init
mapRAM
x
ERR_LOG_CODE_ACCESS_AB_MODE_ERROR
-37
D
Error when setting the assembly
buffer mode
x
ERR_LOG_CODE_NVM_PROTECT_REMOVE_PASSWOR
D_FAILED
-39
D
Removing region password(s)
failed when trying to remove all
region passwords
x
ERR_LOG_CODE_100TP_READ_ADDRESS_INVALID
-43
D
Attempt to read NVM 100TP
address outside of the valid range
x
ERR_LOG_CODE_100TP_WRITE_COUNT_EXCEEDED
-44
D
NVM 100TP page write count was
exceeded
x
ERR_LOG_CODE_100TP_WRITE_ADDRESS_INVALID
-45
D
Attempt to write NVM 100TP
address outside of the valid range
x
ERR_LOG_CODE_CS_PAGE_CHECKSUM
-46
D
NVM config sector checksum
calculation failed
x
ERR_LOG_CODE_CS_PAGE_ECC2READ
-47
D
NVM config sector checksum
calculation failure based on NVM
ECC2 error
x
ERR_LOG_CODE_MBIST_FAILED
-62
D
MBIST test detected an error
x
ERR_LOG_CODE_MBIST_TIMEOUT
-63
D
MBIST test failed due to timeout
x
ERR_LOG_CODE_USERAPI_CONFIG_SECTOR_WRITE_
PROTECTED
-64
D
Not allowed to change values in
write protected config sector
x
ERR_LOG_CODE_USERAPI_CONFIG_SET_PARAMS_IN
VALID
-65
D
Invalid parameters given to
user_bsl_config_set
x
ERR_LOG_CODE_NAD_VALUE_INVALID
-66
D
Invalid NAD value given in
user_nad_set()
x
ERR_LOG_CODE_100TP_PARAM_INVALID
-67
D
user_nvm_100tp_read/write():
Bad data parameter
x
ERR_LOG_CODE_NVM_CONFIG_NOT_READY
-68
D
Data for user_nvm_config_get() is
not available
x
ERR_LOG_CODE_PARAM_INVALID
-69
D
user_nvm_write/branch(): data
parameter is invalid
x
ERR_LOG_CODE_USER_CROSS_PAGE_PRG_NOT_SUP
PORTED
-70
D
user_nvm_write/branch cross-
page programming is not
supported
Table 6-5 List of Possible Errors during Startup
User
API
Error Name
Error
Code
Errors Description