IC6 Operating Manual
AGGREGATE MULTIPLIER
The parameter AGGREGATE MULTIPLY (Yes/No) determines whether an
aggregate multiplier is calculated for this crystal's rate information if a crystal
fails occurs during deposition. This parameter appears on the Material/Sensor
display if Multipoint is set to Yes. This multiplier is used only during the layer in
which the crystal failure occurs. After this layer is finished, the multiplier is
cleared. Default is NO.
(SENSOR) WEIGHT
. . . . . . . . . . . . 1.0 to 400.0 %
The Sensor Weight parameter is used to gauge the relative importance of an
individual sensor's is measured rate in calculating the weighted average,
“aggregate” rate. See
. Default is 100%.
(SENSOR) FAILURE ACTION
and
FAILURE TRIGGER
. . . . . . . . . See
TOOLING: MASTER & SENSOR
The tooling factor is comprised of two parts. The MASTER TOOLING
parameter located in the upper block of the Material/Sensor Set-Up display is
used to scale the aggregate rate and thickness to the substrate. When
Multipoint is set to Yes, additional parameters, including the SENSOR
TOOLING parameter appear in the Sensor Set-Up display area as shown in
MASTER TOOLING
. . . . . . . . . . . . . 10.0 to 400.0 %
The MASTER TOOLING is used as a global tooling factor. This parameter is
used to affect all the sensors' tooling together and calibrate the aggregate rate
and thickness to the thickness measured on the substrate. Default is 100%.
(SENSOR) TOOLING
. . . . . . . . . . . 10.0 to 400.0 %
SENSOR TOOLING is used to account for the geometric tooling factor of each
sensor. The default value is 100%. The calibration procedure for the MASTER
TOOLING can also be applied to the SENSOR TOOLING parameter.
Alternatively each SENSOR's TOOLING factor can be adjusted relative to a
particular sensor. See
.
Содержание IC6
Страница 1: ...O P E R A T I N G M A N U A L IC6 Thin Film Deposition Controller IPN 074 505 P1E Cover Page ...
Страница 2: ......
Страница 8: ......
Страница 20: ...TOC 12 IPN 074 505 P1E IC6 Operating Manual This page is intentionally blank ...
Страница 42: ...1 22 IPN 074 505 P1E IC6 Operating Manual This page is intentionally blank ...
Страница 134: ...6 6 IPN 074 505 P1E IC6 Operating Manual This page is intentionally blank ...
Страница 148: ...8 4 IPN 074 505 P1E IC6 Operating Manual This page is intentionally blank ...
Страница 170: ...9 22 IPN 074 505 P1E IC6 Operating Manual This page is intentionally blank ...
Страница 236: ...11 2 IPN 074 505 P1E IC6 Operating Manual Figure 11 1 The essential advantage of multi point deposition sensing ...
Страница 268: ...13 2 IPN 074 505 P1E IC6 Operating Manual This page is intentionally blank ...
Страница 312: ...15 40 IPN 074 505 P1E IC6 Operating Manual This page is intentionally blank ...
Страница 338: ...A 10 IPN 074 505 P1E IC6 Operating Manual This page is intentionally blank ...
Страница 342: ...1 4 IPN 074 505 P1E IC6 Operating Manual This page is intentionally blank ...