C-Com Satellite Systems Inc
Page 74 of 77
iNetVu™ 5000 Controller User Manual
Revision 1.0.2
Fast Speed / Slow Speed / Calibrate Speed
Default speed values for the automated
processes such as Finding Satellite, Stowing
Antenna, and Calibration processes.
Current Limit
A software controlled current protection for the
Mobile Platform’s motors.
When any of the Mobile Platform’s motors are
moving at the associated speed, the current
drawn to move the motor is monitored and
should it exceed the Current Limit, an error
message will appear. For Motor Speeds that
are not listed (Speed 1, 2, 4, 5, 7, 8), the
Current Limit for those speeds is calculated
using a percentage of the Current Limit above it.
•
Current Limit 8 – 90% of Current Limit 9
•
Current Limit 7 – 80% of Current Limit 9
•
Current Limit 5 – 90% of Current Limit 6
•
Current Limit 4 – 80% of Current Limit 6
•
Current Limit 2 – 90% of Current Limit 3
•
Current Limit 1 – 80% of Current Limit 3
PLATFORM TYPES
MF1200
ME1200
A1200C/
A1200B
A0980B
MF950
ME950
A0950B
EL
FAST
9 9 9 9 9 9 9
EL
SLOW
7 5 4 4 5 4 4
EL
CALIBRATE
7 7 7 7 7 7 7
EL
CURRENT3
1.60 1.60 1.60 1.60 1.60 1.60 1.60
EL
CURRENT6
5.00 5.00 5.00 5.00 5.00 5.00 5.00
EL
CURRENT9
12.50 12.50 12.50 12.50 12.50 12.50 12.50
AZ
FAST
9 9 9 8 8 8 8
AZ
SLOW
6 5 7 4 5 4 4
AZ
CALIBRATE
7 7 7 7 7 7 7
AZ
CURRENT3
1.30 1.80 1.80 1.80 1.30 1.80 1.80
AZ
CURRENT6
3.50 4.50 7 4.50 3.50 4.50 4.50
AZ
CURRENT9
6.00 8.00 8.00 8.00 6.00 8.00 8.00
PL
FAST
9 9 9 9 9 9 9
PL
SLOW
4 4 4 7 7 7 7
PL
CALIBRATE 7 7 7 7 7 7 7
PL
CURRENT3
0.40 0.40 0.40 0.40 0.40 0.40 0.40
PL
CURRENT6
1.20 1.20 1.20 1.20 1.20 1.20 1.20
PL
CURRENT9
1.50 1.50 1.50 1.50 1.50 1.50 1.50