C-Com Satellite Systems Inc
Page 75 of 77
iNetVu™ 5000 Controller User Manual
Revision 1.0.2
PLATFORM TYPES
MF740
ME740
A0740B
A1800A
A0660A
EL
FAST
9 9 9 9 9
EL
SLOW
4 4 4 7 4
EL
CALIBRATE
7 7 7 7 7
EL
CURRENT3
1.60 1.60 1.60 1.60 1.60
EL
CURRENT6
5.00 5.00 5.00 5.00 5.00
EL
CURRENT9
12.50 12.50 12.50 12.50 12.50
AZ
FAST
8 8 8 9 8
AZ
SLOW
4 4 4 6 4
AZ
CALIBRATE
7 7 7 7 7
AZ
CURRENT3
1.30 1.80 1.80 1.80 1.80
AZ
CURRENT6
3.50 4.50 4.50 5.50 4.50
AZ
CURRENT9
6.00 8.00 8.00 9.00 8.0
PL
FAST
9 9 9 9 9
PL
SLOW
7 7 7 4 7
PL
CALIBRATE 7 7 7 7 7
PL
CURRENT3
0.40 0.40 0.40 0.40 0.40
PL
CURRENT6
1.20 1.20 1.20 1.20 1.20
PL
CURRENT9
1.50 1.50 1.50 1.50 1.50
Fig. 61:
Default values for speed and current limits
Disable Limits
Disables UP, DN, and ST limits for testing and
troubleshooting. In the event that a limit is disabled, a
yellow colored “F” will appear in the
Advanced Controls
menu to alert the user that a limit has been disabled.
Speed Current Calibration Enabled
Enables a calibration process that optimizes the current
protection values for the motors and allows for elevation
to be calibrated.
Note:
It is recommended to leave this option disabled.