4. System Power
All iNetVu™ Systems include a DuraComm® LP-18 Power Supply Unit (PSU) which has
been calibrated to give an output of 12.5 VDC for the iNetVu™ 5000 Controller.
An alternate 12VDC power supply
MUST NOT
be used as this
may cause problems with the operation of the mount and/or
irreversibly damage the system. The supplied 12VDC Power
Cable
MUST
be used to connect the iNetVu™ Controller to the
PSU. Failure to adhere to these warnings may void the warranty
of the iNetVu™ System.
For 220VAC users only:
The DuraComm® LP-18 Power Supply has been converted
prior to shipment to meet the requirements of 220VAC. If a replacement DuraComm®
LP-18 is required, please see Appendix 1 for the manual conversion procedure.
The satellite modem, PC control platform, DuraComm® LP-18 Power Supply (if used),
fans, lights, etc. will require AC power. All of these components must be factored in
when surveying mobile power requirements.
Sample Power Requirement Summary:
AC Power Draw
DC Power Draw
Satellite Modem 120W
(Approx. – Check with modem requirements)
iNetVu™ 5000 Controller 200W 12V
Laptop computer 100W
(Approx. – Check with computer requirements)
DuraComm® LP-18 Power Supply 150W
(Approx. - if utilized)
Total 370W AC