Speedway Reader IPJ-R1000 for UHF Gen 2 RFID
74
Appendix C Power Supply Specifications
1
Parameter
Specification
Input
Rated input voltage
100 V ~ 240 V ac
Input voltage range
90 V ~ 264 V ac
Rated frequency
50~60 Hz
Frequency range
47~63 Hz
Rated input current
1.5 A at 115 / 0.75 A at 230 V ac (full load)
Inrush current
nominal ac input voltage at full load, 25°C, cold start
(no damage will occur and the input fuse will not blow)
Output
Output voltage
24 V dc at 2.5 A
Output min. current
0 A
Line regulation
± 2%
Load regulation
± 5%
Over voltage protection
≤
31 V dc max. with zener clamp
Over current protection
≤
5 A (with auto-recovery function)
Short circuit protection
a short circuit at the dc output to ground will cause no damage
Ripple voltage
240 mV (p-p) (at 20 MHz and output parallel with 0.1
µ
F and 10
µ
F
capacitors to ground.)
Efficiency
80% min. (at nominal input voltage and full load)
Safety and EMI
input to output
1500 V ac or 2121 V dc at 10 mA for 1 min.
HI-POT
primary to ground
1500 V ac or 2121 V dc at 10 mA for 1 min.
Safety approvals
UL/cUL (UL60950-1), TUV/GS (EN60950-1), T-license (EN60950-1),
SAA (AS/NZS60950)
EMI standard
FCC part 15 class B, C-Tick, CE (EN55022)
RoHS compliant
yes
Leakage current
0.25 mA
Environmental
Cooling
by natural convection
Storage temperature
-20°C ~ +60° C
Operating temperature
0°C ~ +40° C
Storage humidity
5~95% RH (non-condensing)
Operating humidity
20~85% RH (non-condensing)
Reliability
Mean time before failure (MTBF)
the power supply is designed and produced to have a mean time
between failures (MTBF) of 50,000 hours while operating under the
following conditions: 80% max. load at 25°C, nominal input voltage.
Burn-in test
4 hours at 40°C max., nominal input voltage, 80% of max. load
1
Valid data as of December 2006