Appendix A Impinj Factory Default Configuration
Detailed below are the factory default configuration settings for the Speedway reader. Except for the username and password,
all entries are shown when the “show all config” command is issued on a Speedway reader in its factory default configuration.
Username: root
Password: impinj
Networking Category
Static domain: None
IpAddressMode: dynamic
# (using DHCP to obtain IP address)
hostname: speedway-nn-nn-nn, # where nn-nn-nn are the last three bytes of the reader's MAC address (in hex)
SendHostname: on
Userclass: None
Static DNS server: None
Static NTP server: None
System Info category:
system Description: 'Impinj Speedway'
system Contact: 'http://www.supplier.com/techsupport'
system name: 'speedway-nn-nn-nn'
# same as default hostname
system Location: 'unknown'
Upgrade Agent Category
MetafileUri: Empty
RetrieveMode: push
Logging Category
ApplicationLevel: emergency
ConfigurationLevel: emergency
MgmtLevel: emergency
NetworkLevel: emergency
RFIDParameters Level : emergency
RFIDSingulation Level: emergency
RFIDAccess Level: emergency
System Level: emergency
syslog severityLevel: error
static syslog server: none