LYNX Manual RA02
displayed on the LED by slow pulsation with a 2 second interval – refer to
Status LED section.
Frame rate [fps] = 1 / long integration time [sec] (4.2)
VCCD
Long Integration Time
Standard Frame Time
Figure 2.36 - Long Integration
CAUTION NOTE
1.
During the integration time the camera has to be kept still otherwise a
motion smear will appear on the image.
2.
The minimum value for long integration is camera dependent:
- IPX-VGA210/210-L – 10 ms.
-
IPX-1M48-L – 30 ms.
-
IPX-2M30/H-L – 70 ms.
-
IPX-4M15-L – 120 ms.
-
IPX-11M5-L – 420 ms.
3.
Long Integration cannot be enabled in Trigger mode.
4.
Long Integration cannot be enabled in Programmable Frame Rate
mode.
5.
Long Integration cannot be enabled in Shutter mode.
6.
Long time integration significantly decreases the signal to noise ratio.
More electrons will be collected from the pixels dark current and thus
the camera noise will increase significantly.
www.imperx.com
64
of
154
5/6/2005
Содержание IPX-11M5-L
Страница 28: ...LYNX Manual RA02 IPX 1M48 L Dimensional Drawings Figure 1 10 IPX 1M48 L www imperx com 28 of 154 5 6 2005...
Страница 30: ...LYNX Manual RA02 IPX 4M15 L Dimensional Drawings Figure 1 12 IPX 4M15 L www imperx com 30 of 154 5 6 2005...
Страница 31: ...LYNX Manual RA02 IPX 11M5 L Dimensional Drawings Figure 1 13 IPX 11M5 L www imperx com 31 of 154 5 6 2005...