LYNX Manual RA02
Analog Amplifiers
Command
Syntax
Parm#1
String
returned
Description
Get Analog Offset
gao
0|1|2
i1 i2
Returns the current analog offset for the
specified channel. The parameter indicates
the channel. If the parameter is 0, then both
channels are returned.
Get Analog Gain
gag
0|1|2
i1 i2
Returns the current analog gain for the
specified channel. The parameter indicates
the channel. If the parameter is 0, then both
channels are returned.
Strobe Control
Command
Syntax
Parm#1
String
returned
Description
Get Strobe Position
gsp
off|i
Returns the current strobe position:
off = disabled
i = strobe position in uSeconds
Auto Iris Control
Command
Syntax
Parm#1
String
returned
Description
Get Auto Iris
gai
off|i
Returns the current auto-iris setting:
off = disabled
i = auto-iris threshold
Table A.6 – Workspace ‘GET’ commands
Temperature Control
Command
Syntax
Parm#1
String
returned
Description
Get Temperature Alarm
gta
on|off Returns the current temperature alarm
setting.
Get Temperature Threshold
gtt
t1 t2
Returns the temperature alarm thresholds:
t1 = alarm on temp threshold in degrees C
t2 = alarm off temp threshold in degrees C
Get Current Temperature
i
gct
Returns the current camera temperature.
i = temperature in degrees C.
www.imperx.com