LYNX Manual RA02
Analog Amplifiers
Command
Syntax
Parm#1
Parm#2
Description
Set Analog Offset
sao
0|1|2
i
Sets the analog offset. The first parameter
indicates the channel, 1 or 2, and the
second parameter indicates the offset
ranging from 0 to 255. If the first parameter
is 0, then both channels are set.
Set Analog Gain
sag
0|1|2
i
Sets the analog gain. The first parameter
indicates the channel, 1 or 2, and the
second parameter indicates the gain in dB
ranging from 6 to 40 dB. If the first
parameter is 0, then both channels are set.
Strobe Control
Command
Syntax
Parm#1
Parm#2
Description
Set Strobe Position
ssp
off|i
Sets the strobe position:
off = disabled
i = strobe position in uSeconds
Auto Iris Control
Command
Syntax
Parm#1
Parm#2
Description
Set Auto Iris
sai
off|i
Sets the auto iris operation:
off = disabled
i = auto-iris threshold
Temperature Control
Command
Syntax
Parm#1
Parm#2
Description
Set Temperature Alarm
sta
on|off
Enables temperature monitoring.
Set Temperature Threshold
stt
t1
t2
Sets the temperature alarm thresholds:
t1 = alarm on temp threshold in degrees C
t2 = alarm off temp threshold in degrees C
Table A.5 – Workspace ‘SET’ commands
www.imperx.com
132
of
154
5/6/2005
Содержание IPX-11M5-L
Страница 28: ...LYNX Manual RA02 IPX 1M48 L Dimensional Drawings Figure 1 10 IPX 1M48 L www imperx com 28 of 154 5 6 2005...
Страница 30: ...LYNX Manual RA02 IPX 4M15 L Dimensional Drawings Figure 1 12 IPX 4M15 L www imperx com 30 of 154 5 6 2005...
Страница 31: ...LYNX Manual RA02 IPX 11M5 L Dimensional Drawings Figure 1 13 IPX 11M5 L www imperx com 31 of 154 5 6 2005...