3.8.3 Shutter
Time
3.8.3.1 Set Shutter Time (
‘sst’
)
The
‘sst’
command sets the shutter timing.
Syntax:
sst <off|i>
Parameter:
off
Disables the shutter mode.
i
The shutter time in units of uSeconds.
Range:
i
min=50
max=the lesser of 500,000 or 1/frame rate
Example:
sst 80
Sets the shutter time to 80 uSeconds.
Notes:
The shutter operates in increments of 10 uSeconds
and therefore will round the least significant digit
entered.
3.8.3.2 Get Shutter Time (
‘gst’
)
The
‘gst’
command returns the current shutter setting.
Syntax:
gst
Response:
off|i
Example:
gst
User enters command.
80
Camera responds with current setting.
www.imperx.com