3.8.5 Strobe
Position
3.8.5.1 Set Strobe Position (
‘ssp’
)
The
‘ssp’
command sets the position of the strobe pulse output. The
strobe pulse position is set relative to the start of the frame.
Syntax:
ssp <off|i>
Parameter:
off
Disables
the
strobe.
i
The strobe position in units of uSeconds.
Range:
i
min=10
max=the lesser of 500,000 or 1/frame rate
Example:
ssp 120
Sets the strobe position to 120 uSeconds.
Notes:
The strobe operates in increments of 10 uSeconds and
therefore will round the least significant digit entered.
3.8.5.2 Get Strobe Position (
‘gsp’
)
The
‘gsp’
command returns the current long integration setting.
Syntax:
gsp
Response:
off|i
Example:
gsp
User enters command.
120
Camera responds with current setting.