CHEETAH 3G-SDI Camera
November 16, 2017
Page
12
of
53
Rev 1.1
GREEN blinks at
~ 2.0 Hz
Camera is in external genlock sync mode.
YELLOW steady ON
Test mode. You should see one of the test patterns.
YELLOW blinks at ~ 0.5
Hz
Camera is in AGC/AEC mode. In this mode, changing the shutter
slider does not affect the image luminance.
RED steady ON
RS-232 communication error or firmware load error. Re-power
the camera and load the factory settings. If the condition is still
present, contact the factory for support.
LED OFF
Power not present. Possible power supply failure or faulty
external AC adapter. Re-power camera and load factory
settings. If the LED is still OFF, contact the factory for RMA.
Table 2: LED status indicators on camera.
Example
The follow illustration shows an example setup of C2010 components and
cabling.
Figure 2: C2010 Connection example.
2.1.3 Power Supply
The Cheetah 3G-SDI camera can use a universal desktop power supply adapter
pro12VDC, ± 10% and up to 2.5A DC current available from Imperx (P/N:
PS12V06). The operating input voltage ranges from 90 to 240 VAC.