Force Displays:
18
PEAK SATURATION
TREND ERROR
NOFEED ERROR
BKSTR HI LIM
Next/No
101*157*150 6(3)
Next/No
CHANNEL 1 ERROR
Next/No
(All other errors in
reverse order)
Next/No
END OF ERRORS
(default screen)
Clear
(default screen)
In certain cases, the above two
messages may be replaced by a special
message. “PEAK SATURATION”
would mean that the force input was
higher than IMPAX could measure; an
electronics adjustment may be required.
“TREND ERROR” means that the force
changed very slowly and reached a
previously set trend limit. This is
usually caused by tool wear or some
other slow change. “NOFEED
ERROR” means that too many strokes
have occurred without any forming
force being measured. “BKSTR HI
LIM” means that an excessive force
was measured on the backstroke of the
ram or slide.
Press Next/No. The display now shows
numbers, such as “101*157*150 6(3)”.
This shows the force measurement
which caused the IMPAX to stop the
machine. Note that the middle number
must always be either above the upper
limit or below the lower limit for an
error to occur in force. In this case it is
above the upper limit. The number 6 is
the current tolerance setting. The 3 is
the variance IMPAX is detecting in the
forming process.
Press Next/No. The display will show
“CHANNEL 1 ERROR”.This is
information about the fault which
occurred before the error at 750
(described above). Continuing to press
Next/No will display the faults which
have been recorded in reverse order.
At any time, you may press Back to
return to the beginning of that Error
message. Pressing Back again steps
backward to the beginning of the
previous Error message. Pressing Clear
returns the display to the selected
(default) screen. After the last Error is
displayed, pressing Next/No will
display “END OF ERRORS.”
Refer to
page 10 to clear errors.
Press Display Will Show
or
Only in special or
cases where
certain errors
have occurred!
or
numbers are for example only
At any time during errors:
Содержание 2000
Страница 1: ...2000 Supervisor s Guide ...
Страница 4: ...Specifications Back view of Control Console Satellite Circuit IMPAX Control Console 49 50 51 52 ...
Страница 53: ...DRAWINGS Backview of the Control Console ...
Страница 54: ...Satellite Box Circuitry ...
Страница 55: ...IMPAX 2000 Control Console ...