Setting Tolerances - cont.
10
Enter/Yes
C1 TREND 0%
5
C1 TREND 50%
X
Enter/Yes
(Next option or channel)
Next/No
(Next option or channel)
Enter/Yes
(Next option or channel)
ALL FACTORS SET
Trend Setting
After the Tolerance has been set for the
first channel, press the Enter/Yes key.
If Trending is turned on in Channel
Definition, the next display will show
“C1 TREND 0%”. By entering a
number here from 1 to 99, you can limit
the amount that the force measurement
can drift due to gradual changes such as
tool wear. For example, pressing 50
displays “C1 TREND 50%”, which will
stop the machine after the force changes
(gradually) by 50%; you would then
clean or replace the tool. Set the Trend
Factor by pressing the Enter/Yes key.
Exception Setting
If Exceptions are turned on in Channel
Definition, the next display will show
either “C1 CUMU EX 0" or “C1
CONS EX 0." An exception is an
IMPAX detected error which you can
allow the monitor to ignore. This
feature is extremely useful if you have a
diverter installed on the machine. If a
diverter is installed, you can set one of
the relays to be an exception relay and it
will trip the diverter and divert the part
without stopping the machine.
“CUMU” stands for cumulative. This
means that IMPAX will allow a certain
number of errors out of 100 to be
ignored. For example, if I set the
number to 2, IMPAX would allow 2
parts out of 100 to exceed either the HI
or the LO limit without shutting down
the machine.
“CONS” stands for consecutive. This
means that IMPAX will allow a certain
number of errors in a row to be ignored.
Press Display Will
Show
(Trend can be set from 1% to 99%)
For Example:
These options will only be available if
turned on in Channel Definition in
programming.
To permit exceptions, backstrokes, and/or low
force readings:
(All described below)
X can be from 1 to 9,999
To not permit exceptions, backstrokes, and/or
low force readings:
or
Once all tolerances, fixed limits, excpts, nofeeds,
and trend information is set: