Guarantees the flow of air in the sealed chamber and the escape of combustion products.
It is powered by the integrated P.C.B. via a signal with square wave detected using a sensor
wit Hall effect inserted into the fan, which allows the integrated P.C.B. to measure its speed
and correct it if it does not comply with the requested value.
Fan
(M20)
Outputs
Displays the functioning values and error codes intervening on the boiler. Moreover, it
indicates the status and functioning mode of the boiler by means of appropriate symbols.
Display board
(A4)
Management and control devices
Allows long distance control of the generator (SUM/WIN fun-
ctioning, temperature adjustment and indication, programs and
parameters setting alarms display, reset, etc.) and acts as weekly timer
thermostat.
If the Super CAR is installed the pre-existing X40 jumper must
be eliminated.
Using the Super CAR it is possible to indifferently vary some settings
from the boiler control panel and from the Super CAR control
panel, such as: selection of Summer Winter, DHW comfort status,
DHW set point.
Super CAR
(optional)
See Super CAR
functioning
Allows long distance control of the generator (SUM/WIN selector
switch, temperature adjustment and indication, alarms display, reset,
etc.) and acts as weekly timer thermostat.
If the CAR is installed the pre-existing X40 jumper must be eli-
minated.
Comando Amico Remoto
remote control
(CAR) (optional)
See Comando
Amico Remoto
remote control
functioning
(CAR)
Allows the control of 1 additional zone valve by means of CAR, which must be set in On/
Off mode (see CAR functioning).
P.C.B. to a relay
(optional)
Allows boiler functioning with 3 zone valves or external pumps
controlled by the respective room thermostats.
The main area is controlled(times and temperatures) by means of
the remote control (if mounted), on which the pump anti-blocking
and post-circulation, anti-freeze, chimney sweep functions etc.
take place.
Zones control unit (CZ)
(external optional)
See zones control
unit functioning
Regulations via selectors
Pump mode selector
switch
(S10)
With the SUM/WIN selector switch in the WINTER position, it
allows the pump to function continuously or only on request of
the room thermostat.
Absent =
Continuous func.
Present =
RT request func.
Central heating tempera-
ture range selector switch
(S13)
Depending on the position, it allows the central heating potentio-
meter to adjust the temperature from 25 to 85°C (range 1) or from
25 to 50°C (range 2).
Present = 25-85
Absent = 25-50
At every switch-off due to the temperature being reached in CH
mode a delay of 3 minutes/30 seconds is inserted until the successive
re-ignition for the same request.
Central heating timer
selector switch
(S7)
Absent = 30 s
Present = 3 min
Domestic hot water mode
selector switch
(S9)
Allows to modify the temperature difference from the set-point
at which the DHW ("Storage tank ON intervention temperature")
request is activated.
Absent =
Setpoint-10°K
Present =
Setpoint-3°K