35
STVZ1I ed 10/09
VICTRIX Zeus 1 I
Technical Documentation
Technical Documentation
Technical Data
VICTRIX Zeus 1 I technical data
- Flue temperature values refer to an air inlet temperature of 15°C
and flow temperature of 50°C.
-The data relevant to domestic hot water performance refer to a dy-
namic inlet pressure of 2 bar and an inlet temperature of 15°C; the
values are measured directly at the boiler outlet considering that to
obtain the data declared mixing with cold water is necessary.
- The maximum sound level emitted during boiler operation is <
55dBA. The sound level value is referred to semianechoic chamber
tests with boiler operating at max. heat output, with extension of
flue gas exhaust system according to product standards.
- * Specific capacity “D”: domestic hot water flow rate corresponding
to an average increase of 30K, which the boiler can supply in two
successive withdrawals.
Domestic hot water nominal heat input
kW (kcal/h)
26,9 (23147)
Central heating nominal heat input
kW (kcal/h)
24,4 (20941)
Minimum heat input
kW (kcal/h)
3,2 (2768)
Domestic hot water nominal heat output (useful)
kW (kcal/h)
26,0 (22360)
Central heating nominal heat output (useful)
kW (kcal/h)
23,6 (20296)
Minimum heat output (useful)
kW (kcal/h)
3,0 (2580)
Efficiency 80/60 Nom./Min.
%
96,9 / 93,2
Efficiency 50/30 Nom./Min.
%
105,3 / 106,8
Efficiency 40/30 Nom./Min.
%
107,5 / 108,8
Heat loss at casing with burner On/Off (80-60°C)
%
0,58 / 0,90
Heat loss at flue with burner On/Off (80-60°C)
%
0,03 / 2,50
Central heating circuit max. operating pressure
bar
3
Central heating circuit max. operating temperature
°C
90
Adjustable central heating temperature Pos 1
°C
25 - 85
Adjustable central heating temperature Pos 2
°C
25 - 50
System expansion vessel total volume
l
4,2
Expansion vessel factory-set pressure
bar
1
Water content in generator
l
4,2
Total head available with 1000/h flow rate
kPa (m c.a.)
19,40 (1,98)
Hot water production useful heat output
kW (kcal/h)
26,0 (22360)
Domestic hot water adjustable temperature
°C
20 - 60
Domestic hot water circuit flow limiter at 2 bar
l/min
9,4
Min. pressure (dynamic) domestic hot water circuit
bar
0,3
Domestic hot water circuit max. working pressure
bar
8
*Specific capacity “D” according to EN 625
l/min
15,6
Drawing capacity in continuous duty (∆T 30°C)
l/min
13,3
Weight of full boiler
kg
108,6
Weight of empty boiler
kg
61,3
Electrical connection
V/Hz
230/50
Power input
A
0,61
Installed electric power
W
135
Pump consumption
W
87,2
Fan consumption
W
25,6
Equipment electrical system protection
-
IPX4D
Flue gas max. temperature
°C
75
NO
X
class
-
5
Weighted NO
X
mg/kWh
21,3
Weighted CO
mg/kWh
16,9
Type of appliance
C13 / C23 / C33 / C43 / C53 / C83 / B23p
/ B33
Category
II2H3B/P