230 VDC are present on the L-N terminals of the P.C.B.
No
Check the electric power supply upstream from the boiler and restore
it.
Yes
The P.C.B. fuses are integral.
No
See section E
Yes
230 VDC are present to the clamps 3-4 of connector X4 on the
P.C.B.
No
Replace the P.C.B.
Yes
At least 19 VDC are present to the clamps 1-2 of connector X11 on
the P.C.B.
No
Restore the electric connection/replace the transformer.
Yes
The wiring between the P.C.B. and display board is OK.
No
Restore the electric connection/replace the wiring.
Yes
Replace the P.C.B. If the anomaly persists, replace the display board.
B
230 VDC are present to the clamps 1-2 of connector X6 on the
P.C.B.
No
Replace the P.C.B.
Yes
230 V DC are present on the pump clamps.
No
Restore the electric connection/replace the wiring.
Yes
The motor shaft turns freely.
No
Release the pump by acting on the shaft after having loosened the
front cap.
Yes
The start-up condenser is integral.
No
Replace the condenser.
Yes
Replace the pump.
C
CENTRAL HEATING MODE:
230 VDC are present to the clamps 1-3 of connector X5 on the
P.C.B.
DOMESTIC HOT WATER MODE:
230 VDC are present to the clamps 1-2 of connector X5 on the
P.C.B.
No
Replace the P.C.B.
Yes
The wiring between the 3-way motor and the board is OK.
No
Restore the electric connection/replace the wiring.
Yes
The 3-way cartridge functions regularly (it is not blocked).
No
Release/replace the 3-way cartridge.
Yes
Replace 3-way valve motor.
D
The gas valve is calibrated correctly.
No
Regulate the CO
2
values to Minimum and Maximum (see air gas
regulation paragraph).
Yes
The NTC flow probe is OK (10 kΩ at 25°C).
In DHW functioning mode, also check the DHW NTC probe.
No
Replace NTC probe.
Yes
Replace the P.C.B.
E
The operations stated below are indispensable for checking the quality of the relay electric contacts positioned on the board.
Replace the fuses checking that there are no short circuited components (pump, fan, gas valve, etc...).
Check safety device times and the complete power removal from the gas valve, operating as follows:
- close the gas supply and make a functioning request;
- check that, after 2 ignition attempts, the display shows error "01";
- with the help of the single wire wiring diagram, use a tester to check that there is no voltage (230 V DC) on the gas valve power supply cables.