38
STVZ1I ed 10/09
VICTRIX Zeus 1 I
Technical Documentation
Technical Documentation
Apply voltage to the boiler and turn the main selector to the "summer" or "winter" position.
The display switches on
No
See section A
Yes
The error 05 appears on the display
Yes
See error section 05
The error 08 appears on the display
Yes
See error section 08
The error 12 appears on the display
Yes
See error section 12
The error 16 appears on the display
Yes
See error section 16 - a
The error 20 appears on the display
Yes
See error section 20
The error 37 appears on the display
Yes
See error section 37
No
Before every intervention:
Check that the gas, water and electricity are correctly connected
to the boiler, according to that indicated in the data plate and
the instruction manual.
Also make sure that:
- the gas valve and boiler parameters are correctly adjusted;
- all devices outside the boiler function and are appropriately
adjusted;
- the external and internal fuses are integral.
Before maintenance interventions or replacement of compo-
nents, remove the electric power supply upstream from the
appliance.
For correct use of the troubleshooting table, on intervention it
is recommended to reset any errors, switch the boiler off and
remove voltage from the appliance for at least 5 seconds.
This is to allow the boiler to start a new ignition cycle.
Ignition cycle
CENTRAL HEATING MODE
Main selector switch in winter position.
Turn the heating selector to a maximum and interrupt and DHW re-
quests.
The pump starts.
No
Check the presence of the TA jumper on clamps
40-41 of the P.C.B.
N.B.: the jumper must not be present when
external devices are installed such as TA, remote
control, clock programmer, etc...
Check effective request (the
symbol is displa-
yed), from any external devices (TA, remote con-
trol, programmer clock). See error section 31.
No
See section B
Yes
The 3-way valve goes
into the CH posi-
tion.
No
See section C
DOMESTIC HOT WATER MODE
Main selector switch in summer position.
Turn the DHW selector switch to maximum and open the cock.
The (
) symbol is displayed.
The pump starts.
No
See section B
Yes
The 3-way valve goes
into the DHW po-
sition.
No
See section C
Yes
The pump starts.
No
The error 10 appears on the display
See error section 10
No
The error 15 appears on the display
See error section 15
No
The error 16 appears on the display
See error section 16 - b
Yes
The error 16 appears on the display Yes
See error section 16 -c
No
The ignition electrodes make the
spark.
No
The error 01 appears on the display
(wait for the board to make 2 ignition cycles).
See error section 01 - a
Yes
The burner ignites.
No
The error 01 appears on the display
(wait for the board to make 2 ignition cycles).
See error section 01 - b
No
The error 02 appears on the display
See error section 02 - a
VICTRIX Zeus 1 I troubleshooting
Содержание VICTRIX Zeus 26 1 I
Страница 2: ......