40
STVZ1I ed 10/09
VICTRIX Zeus 1 I
Technical Documentation
Technical Documentation
ERROR 01
No ignition block
01
a
230 V DC are present on clamps 2-3 of connector X7.
No
Replace the P.C.B.
Yes
There are 230 Vdc present at the ends of the igniter.
No
Replace the wiring.
Yes
The cables between igniter and electrodes corresponds.
No
Restore the electric connection/replace the wiring.
Yes
The igniter makes the spark.
No
Replace the igniter.
Yes
Check the correct positioning and the correct distance of the ignition electrodes (see air-gas circuit) and replace them if necessary.
01
b
230 V DC are present on clamps 6-7 of connector X7.
N.B: measure the voltage within the safety time (8-10 s).
No
Replace the P.C.B.
Yes
The connector and relative wiring between gas valve and P.C.B.
are OK.
No
Restore the electric connection/replace the wiring.
Yes
The position and the distance of the ignition electrodes with respect
to the burner is OK (see air-gas circuit).
No
Restore the position and the distance of the ignition electrodes.
Yes
Replace the gas valve.
N.B.: before replacing the valve make sure that there is enough gas inlet dynamic pressure and that the gas valve is correctly calibrated.
01
c
The electrode detects a direct current of 6-8 µA during the burner
ignition phase.
No
Replace the detection electrode and/or relative wiring.
Check correct position and distance between electrode and burner.
Check that siphon and the condensate exhaust duct are not blocked.
Yes
There are no combustion products in the air intake pipe.
N.B.: check the absence of CO
2
or other combustion products in the
intake pipe.
No
Check the correct positioning of the terminals, of all joints and
gaskets, to prevent the recirculation of the combustion products inside
the pipes.
N.B.: The error 01 could be preceded by the display of error 38.
Yes
Replace the P.C.B.
ERROR 02
Over-heating safety thermostat block
02
a
The wiring between the safety thermostat, flue safety thermostat
and P.C.B. is OK.
No
Restore the electric connection/replace the wiring.
Yes
The flue safety thermostat functions regularly (intervention tempe-
rature higher than 110°C).
No
Replace the flue safety thermostat.
Yes
The safety thermostat functions regularly (intervention temperature
higher than 100°C).
No
Replace the over-heating safety thermostat.
Yes
Replace the P.C.B.
Functioning anomalies.