Parameter
Parameter
Description
Range
Default
Customised
value
P0
DHW max
Defines the maximum heat output percentage of the boiler during the D.H.W.
phase compared to the maximum heat output available
0 - 99 %
99%
P1
Min output
Defines the minimum heat output percentage of the boiler compared to the
minimum heat output available
0 - P2
0%
P2
Heating max
Defines the maximum heat output percentage of the boiler during the central
heating mode compared to the maximum heat output available
0 - 99%
according
to the boiler
model
P3
Relay 1
(optional)
The boiler is set-up for functioning with the relay P.C.B. (optional), which
can be configured
0
= Off
1
= Main zone control
2
= General alarm
3
= CH phase active
4
= External gas valve power supply
5
= (Do not use on this boiler model)
6
= (Do not use on this boiler model)
7
= (Do not use on this boiler model)
0 - 7
1
P4
Relay 2
(optional)
The boiler is set-up for functioning with the relay P.C.B. (optional), which
can be configured
0
= Off
1
=General alarm
2
= CH phase active
3
= External gas valve power supply
4
= Secondary zone control (from TA on relay P.C.B. contact)
5
= Heat pump
6
= (Do not use on this boiler model)
7
= (Do not use on this boiler model)
0 - 7
0
P5
Relay 3
(optional)
The boiler is set-up for functioning with the relay P.C.B. (optional), which
can be configured
0
= Off
1
= Chiller remote activation
2
=General alarm
3
= CH phase active
4
= External gas valve power supply
5
= heat pump
6
= activation of storage tank recirculation
7
= Main zone control
8
= (Do not use on this boiler model)
9
= (Do not use on this boiler model)
0 - 9
0
P6
Pump function-
ing
The pump can function in two ways.
0 intermittent: in winter "mode" the circulator is managed by the room
thermostat or by the remote control
1 continuous: in "winter" mode the circulator is always powered and is
therefore always in operation
0 - 1
0
P7
External probe
correction
If the reading of the external probe is not correct it is possible to correct it
in order to compensate any environmental factors.
(Over the value of +9 the display shows “CE”, which enables an external con-
trol function of the boiler for coupling of the same with a system supervisor)
-9 ÷ 9 K
0
P8
-
Not used on this boiler model
-
-
STD.002549/004