26
3-1
INS
TALLER
US
ER
MAINTEN
AN
CE TECHNI
CI
AN
3
BOILER COMMISSIONING
(INITIAL CHECK)
To commission the boiler:
- ensure that the type of gas used corresponds to
the boiler settings (the type of gas appears on
the display on first electrical power supply, or
by checking the relative parameter “G”);
- check connection to a 230V-50Hz power
mains, correct L-N polarity and the earthing
connection;
- make sure the central heating system is filled
with water and that the pressure gauge indicates
a pressure of 1-1.2 bar.
- switch the boiler on and check correct ignition;
- check the CO
2
flow rate in the flue:
- maximum (100%)
- intermediate (50%)
- minimum (0%)
the values must comply with what is indicated
in the relative table (Fig. 3-14);
- check activation of the safety device in the event
of no gas, as well as the relative activation time;
- check the intervention of the main switch lo-
cated upstream of the boiler and in the boiler;
- check that the intake and/or exhaust terminals
are not blocked;
- ensure activation of all adjustment devices;
- check the production of DHW (when the boiler
is connected to an
external storage tank unit)
;
- check sealing efficiency of water circuits;
- check ventilation and/or aeration of the instal-
lation room where provided.
If even only a single safety check offers a negative
result, do not commission the system.
3.1 BOILER HYDRAULIC DIAGRAM.
Key:
1 - Gas valve
2 - Filling cut-off valve
3 - Condensate drain trap
4 - System filling valve
5 - System expansion vessel
6 - Condensation module
7 - Air / gas mixer
8 - Fan
9 - Ignition / detection electrode
10 - Air sample point
11 - Flue sample point
12 - Flue probe
13 - Manual vent valve
14 - Flow probe
15 - Safety flow probe
16 - Vent valve
17 - Boiler circulator pump
18 - System pressure switch
19 - Three-way valve (motorised)
20 - By-pass
21 - System draining valve
22 - 3 bar safety valve
23 - 3 bar safety valve drain fitting signal
G - Gas supply
RU - Storage tank unit return (optional)
MU - Storage tank unit flow (optional)
RR - System filling
SC - Condensate drain
R - System return
M - System flow