37
STV50 ed 09/08
VICTRIX 50 Rev. 002
Technical specifications.
Technical specifications, VICTRIX 50.
- The flue temperature values refer to an inlet temperature of
15°C and a flow temperature of 50°C.
- The maximum sound power emitted while the boiler is
working is < 55dBA. This measurement refers to tests in a
semi-anechoic chamber with the boiler working at maximum
heat output and with the extension of the flue accessories
complying with product standards.
Nominal heat input
kW (kcal/h)
50,8 (43655)
Minimum heat input
kW (kcal/h)
10,4 (8958)
Nominal (useful) heat output
kW (kcal/h)
50,0 (43000)
Minimum (useful) heat output
kW (kcal/h)
10,0 (8600)
Effective efficiency 80/60 Nom./Min.
%
98,5 / 96,0
Effective efficiency 50/30 Nom./Min.
%
106,0 / 106,5
Effective efficiency 40/30 Nom./Min.
%
107,0 / 107,0
Casing losses with burner On/Off (80-60°C)
%
0,47 / 0,20
Chimney losses with burner On/Off (80-60°C)
%
0,02 / 1,30
Maximum working pressure of heating circuit
bar
4,4
Maximum working temperature of heating circuit
°C
90
Heating temperature adjustment
°C
20 - 85
Available head with 1000/h flow rate
kPa (m H
2
O)
55,4 (5,65)
Full boiler weight
kg
66,7
Empty boiler weight
kg
63,0
Generator water capacity
l
3,7
Power supply connection
V/Hz
230/50
Nominal power input
A
0,85
Installed electrical power
W
180
Pump power absorption
W
115
Fan power absorption
W
59
Appliance electrical insulation
-
IPX5D
Max. ambient operating temperature
°C
+50
Min. ambient operating temperature
°C
-5
Min. ambient operating temperature with (optional) antifreeze kit
°C
-15
Max. flue gas temperature
°C
75
NO
X
class
-
5
Weighted NO
X
mg/kWh
55,0
Weighted CO
mg/kWh
37,6
Type of appliance
C13 / C33 / C63 / B23 / B33
Category
II2H3B/P
Technical Documentation
Technical Documentation